SBIR/STTR Research Award

Phase-Doppler interferometry probe for high efficiency characterization of cloud droplets

Award identifier c5798fa5f0bbb8d316d5b066dda5a6a80256e6138a740e758713fae4c52ada42Awarding agency Department of Energy

Award amount

$249,780

Program and phase

SBIR · Phase I

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
ARTIUM TECHNOLOGIES, INC.
Proposal award date
2021-02-22
Contract end date
2021-11-21
UEI
N1AJHHKCXAV1
Solicitation number
Not reported
Topic code
30b

Research abstract

This proposed effort addresses the need for accurate and reliable cloud droplet size distribution measurements with a sufficient data rate to characterize spatial variations in cloud formations. Currently used instrumentation for airborne measurements of clouds have been found to have limitations in terms of accuracy for both cloud droplet size and liquid water content (LWC) measurements. In addition, the limited sampling cross-section of these instruments requires unacceptable sampling times to acquire size distributions and thus limit the measurements of spatial variations in the clouds. The phase Doppler interferometry (PDI) method has been independently demonstrated to provide accurate high- resolution measurements of droplet size and velocity. When applied from tethered balloons or drones, the method can also measure turbulence fluctuation droplet response to the microscale turbulence. Development of the phase Doppler method to be able to function with much larger sampling cross sections will provide a much higher data rate, and consequently, size distribution and LWC measurements over a shorter flight path length. However, as with existing instrumentation, PDI is also susceptible to droplet coincidence measurement errors which occurs when more than one droplet is present in the sample volume at the same time. Increasing the sample volume size of the phase Doppler method will exacerbate this problem. Innovative means are described in this proposal to cope with this problem and to generate reliable measurements even under conditions of significant coincident events. The key advantage of the PDI method is that the signals have unique sinusoidal character which can be easily detected in the presence of noise and can be used with higher level signal processing with the discrete Fourier transform (DFT) to reliably detect and measure the frequency and phase of the signals. Under coincident conditions, advanced signal processing using signal amplitude, frequency, phase, and signal-to-noise ratio allow parsing of the individual signals to obtain their size and velocity. Thus, coincident events can be reconciled to provide reliable and accurate measurements of the individual droplet sizes and velocities. Under this proposed effort, the signal parsing method will be tested on a breadboard system and compared to measurements with our standard PDI instruments. In addition to the parsing method to mitigate coincident errors, the instrument will include selectable apertures in the receiver to allow the sample volume size to be adapted to the prevailing cloud droplet number density conditions. Although the cloud measurement instrumentation market is relatively limited, there are numerous other applications for spray measurements in dilute spray environments. Currently, the PDI method is being used to characterize droplets generated by speaking and while sneezing which is of concern for spreading the COVID-19 virus. These droplet clouds are very dilute and require much larger sampling volume to improve the efficiency of the measurements. The PDI instrument is also used for measuring antiviral sprays used for decontamination of building interiors. In the area of dense sprays, the signal parsing approach will be very useful in measuring dense sprays associated with gas turbine and automotive fuel injection systems. Thus, this development will be highly useful in terms of advancing spray measurement instrumentation in multiple industries, several of which are solving environmentally-related human health issues.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

31 SBIR/STTR records share this UEI (1999–2025). Reported award amounts total $13,036,687. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Defense, National Aeronautics and Space Administration, Environmental Protection Agency, Department of Health and Human Services, Department of Commerce, Department of Energy

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.