Research abstract
Project Summary/Abstract
Measuring alcohol consumption is important to individual health and the prevention of adverse
consequences of drinking. There are tremendous needs for wearable alcohol continuous sensing
devices that are accurate, minimal- or non-invasive, unobstructive and affordable. However,
existing technologies cannot provide alcohol sensors with all specifications desired by wearable
devices, including size, power, sensitivity, specificity, safety, manufacturability and cost. The
proposed project is to develop an alcohol sensor suitable for wearable applications by innovating
electrochemical alcohol sensors. The innovation uses microfabrication techniques to achieve high
sensitivity, high safety, good manufacturability and low cost with a miniaturized membraneless
structure. The catalytic effect of the designed electrolyte-electrode interface achieves high
sensitivity and high selectivity. The size of the sensor is less than 2x2 millimeters, can unlock
many possibilities for wearable, smartphone, and automobile for alcohol detection in breath,
interstitial fluid, or blood. In this project, we aim to demonstrate the technology by an examplary
ring form factor wireless powered wearable device that can accurately and continuously monitor
the alcohol level in body fluid. In Phase I, in addition to the alcohol sensor, a minimal invasive
biocompatible microneedle array is designed to painlessly sample and deliver the interstitial fluid
to the sensor. The microneedle array is designed to be processed along with the sensor on the
same silicon substrate. The entire process is compatible with the fabrication of complimentary
oxde metal semiconductor (CMOS), allowing the further monolithic integration of the microneedle
array, the alcohol sensor, and the CMOS sensor readout integrated circuit (IC) in Phase II.Project Narrative
The microfabricated electrochemical alcohol sensor is advantageous to wearable devices for its
size, power, selectivity, cost, and manufacturability. In aid of minimal invasive sampling through
microneedle array, it enables a wearable device to continuously, accurately and painlessly
evaluate the wearer’s alcohol consumption without intervention. Such a device would help lower
the risk of adverse health, safety, legal and social consequences.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
Research funding history
3 SBIR/STTR records share this UEI (2019–2024). Reported award amounts total $798,373. Reported amounts are not federal obligations.
Phases: Phase I
Agencies: Department of Health and Human Services, National Science Foundation
Agency intelligence
Department of Health and Human Services
Back to SBIR/STTR Research Awards