Explore This Research Award in CaptureIQ
Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.
Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- BIOLIGHT ENGINEERING LLC
- Proposal award date
- 2020-09-30
- Contract end date
- 2022-08-31
- UEI
- UTXFNMYFB536
- Solicitation number
- PA19-272
- Topic code
- N
Research abstract
Title: A portable ultra-widefield fundus camera for nonmydriatic examination of retinopathy of prematurity
Summary: Prompt screening is an essential step to prevent visual impairment and blindness due to retinopathy
of prematurity (ROP). It is known that widefield fundus examination is essential for ROP screening, diagnosis
and treatment evaluation. However, existing pediatric fundus cameras have three major limits: limited field of
view (FOV), high cost, and mydriatic imaging. This SBIR is to develop a pediatric camera (PedCam) which is an
ultra-widefield (220o), low-cost ($25K), and non-mydriatic device to overcome all three limits of existing fundus
cameras. In Phase I, we have constructed a lab prototype for proof-of-concept validation, and demonstrated the
feasibility of using trans-pars-planar illumination for ultra-widefield fundus photography. By freeing the whole
available pupil for imaging purpose only, the trans-pars-planar illumination significantly simplifies optical design
of the PedCam. During the Phase II, we propose to optimize the optical design, standardize the fabrication
process of key components, develop an easy-to-use imaging platform, and validate the PedCam for ROP
screening. The first aim is prototype development of a 220° PedCam. Key specifications of the proposed device
are: 220° FOV in a single-shot image; 20 µm resolution for central retina; and 40 µm for peripheral retina. In
coordination with a near infrared guidance to minimize the visible light exposure to the retina, a three-channel
illuminator will allow easy identification of the pars plana to enable high illumination efficiency with optimal image
quality. The second aim is clinical validation of the 220° PedCam for ROP screening. For quantitative comparison,
fundus images will be acquired using both the prototype PedCam and a clinical RetCam3 at UIC Retina Clinic.
Binocular indirect ophthalmoscopy (BIO) will be used for standard ROP examination. Success criterion of the
Phase II study is to verify that the non-mydriatic PedCam can provide performance superior to that of the
mydriatic Retcam; and to demonstrate the potential of using the 220° PedCam for comprehensive pediatric
fundus examination up to the ora serrata, which is not currently possible with the 130° Retcam. By the end of
the phase II, technical specification of the 220o PedCam will be finalized for the 510(k) preparation required for
FDA clearance.Project Narrative
This SBIR is to develop a 2200 pediatric camera (PedCam) for retinopathy of prematurity (ROP) screening. In
coordination with unique trans-para planar illuminator, the 2200 PedCam will be a low-cost, portable and non-
mydriatic device to foster clinical deployments of digital fundus photography for ROP management.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Research funding history
3 SBIR/STTR records share this UEI (2016–2020). Reported award amounts total $1,605,607. Reported amounts are not federal obligations.
Phases: Phase I, Phase II
Agencies: Department of Health and Human Services
Agency intelligence
Department of Health and Human Services