Explore This Research Award in CaptureIQ
Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.
Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- NUBORN MEDICAL INC
- Proposal award date
- 2020-09-16
- Contract end date
- 2021-08-31
- UEI
- CSFEDJCD2DA6
- Solicitation number
- PA19-270
- Topic code
- NICHD
Research abstract
PROJECT SUMMARY/ABSTRACT
Ten percent of the approximately four million infants born in the United States each year are
born premature (andlt;37 weeks gestational age). Preterm birth prior to the maturation of critical
neonatal body systems results in prolonged hospitalizations that impose an annual societal cost
burden of $26 billion. Achievement of the ability to fully orally feed is often the last
developmental milestone these infants achieve, with the time it takes for patients to meet this
milestone accounting for as much as 89.5% of the variance of their total length of hospital stay.
In addition to prolonging neonatal hospital stays these swallowing deficits (dysphagia) pose
detrimental health effects including pulmonary aspiration, cardiopulmonary instability, and
malnutrition. Early diagnostics and treatment are critical to maximizing neonatal health
outcomes and reducing hospital expenditures. While the gold standard videofluoroscopic
swallow study is an effective diagnostic method, its emission of harmful radiation limits its
regular clinical utilization. The available alternative assessment, clinical observation, is
subjective with inherent limitations in its validity of detecting underlying deficits. nuBorn
Medical has developed a smart bottle that allows for the non-invasive objective identification of
internal swallowing deficits. With this tool clinicians can identify swallowing deficits and
determine the appropriate treatment regimens to enable earlier and more accurate methods of
dysphagia management than in the current standard of care. In this Phase I STTR investigation,
nuBorn Medical’s generation II smart bottle will undergo technical validation testing as well as
clinical pilot testing to prepare for a Phase II validation investigation.NARRATIVE
As many as 90% of preterm infants will suffer from the negative health complications and
expensive hospital stays that result from untreated swallowing deficits. nuBorn Medical is
developing the first validated smart bottle system that allows for the non-invasive identification
of these deficits during a typical bottle feed. This device will allow clinicians to provide earlier,
more effective treatments so that preterm infants can eat safely and leave the hospital sooner.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
Research funding history
2 SBIR/STTR records share this UEI (2020–2024). Reported award amounts total $1,876,506. Reported amounts are not federal obligations.
Phases: Phase II, Phase I
Agencies: Department of Health and Human Services
Agency intelligence
Department of Health and Human Services
Back to SBIR/STTR Research Awards