SBIR/STTR Research Award

Novel outside-in dialyzer with long filter life and reduced anticoagulation therapies

Award identifier 609a85f9083ae8a397feaa594023a9b5fc56b7e89bd8e3881c605c13a4fbee7cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,999,998

Program and phase

SBIR · Phase II – Direct to Phase II

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Novaflux Inc.
Proposal award date
2020-09-15
Contract end date
2022-08-31
UEI
EB2BHWSBLZT3
Solicitation number
PA19-272
Topic code
400

Research abstract

7. Project Summary/Abstract [Revised] For the past 60 years all hollow fiber dialyzers have had intraluminal blood flow. Novaflux outside-in filtration (OIF) creates a new design paradigm for hollow fiber dialyzers, changing dialyzer flow distribution so that blood flows on the outside of the fiber and dialysate flows in the intraluminal space. This development reduces the need for anticoagulation for acute or chronic dialytic therapies, including hemodialysis (HD) and provides increased filter life for continuous renal replacement therapies (CRRT). In vitro data using conventional dialyzers with OIF flow have found increased filter life to over 100 hours as compared to ~24 h with standard flow with statistically equivalent clearance. In OIF, thrombi have a minimal effect on the blood flow or filter pressure, diffusive clearance, or filtrate flux due to dynamic three-dimensional interconnected flow channels created in the inter fiber space.Novaflux research has developed prototype fibers that reverse the conventional dialyzer membrane structure to provide a thin tight smooth hemocompatible outer skin. The OI fiber will prevent damage to blood cells or formation of platelet aggregates. Novaflux OI filter housings optimize the blood inlet design using novel flow geometries, modeling and computation flow dynamics to provide steady blood velocity and uniform blood flow distribution. OIF dialyzers will be able to be produced by current dialyzer production equipment with relatively minor modifications.The value proposition of OI dialyzers is to reduce or eliminate the need for anticoagulation for chronic hemodialysis. This brings about key benefits including: 1) Lowering risk of heparin related complications such as bleeding and blood loss post treatment; 2) Providing a no-anticoagulation alternative for Heparin-Induced Thrombocytopenia; 3) Lowering the cost by $0.70 to $1.60 per treatment due to reduction in the use of heparin; 4) Reduction of microemboli which may pass from the extracorporeal circuit to the patient, causing ischemic lesions in organs such as the brain, which may contribute to dialysis dementia; and 5) Lower clotting potential facilitates development of wearable renal treatments.The OI filter can help acute dialytic renal treatments by providing no or reduced anticoagulation and longer filter life in CRRT, which translates into: 1) Lower cost and complexity for the healthcare provider; and 2) Reduced need for complex anticoagulation regimes, e.g., regional citrate anticoagulation.The Phase II will scale up the OIF membrane and housings to produce prototype OI dialyzers for in vitro and animal studies to characterize performance and hemocompatibility. These studies will quantify the potential of OI technology to eliminate or reduce anticoagulation for dialytic therapies and to provide clinical benefits and cost reductions compared to current acute and chronic therapies. The Specific Aims of this two year program are: Aim 1: Development of pilot scale production of OI fiber; Aim 2: Design the housing for the outside-in filter based on CFD analysis and develop the dialyzer manufacturing/construction process for limited production runs; Aim 3: To perform Ex vivo testing for the OI membrane and OI filter; and Aim 4: To perform in vivo animal testing in the sheep model. The OI technology will also enable the development of wearable technologies due to inherent benefits of longer filter life.8. Project Narrative This project is to develop a prototype outside-in (OI) dialysis filter that have shown in preliminary studies to achieve andgt;100 hours filter life without clogging or increase in filter pressure gradient. An asymmetric OI hollow fiber (membrane layer at the outside surface) based on the FDA approved polyethersulfone- polyvinylpyrrolidone (PES-PVP) has been developed for the first time. The main tasks are developing and producing pilot build OI filters and testing them both in vitro and in the sheep model for hemodialysis.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2019–2023). Reported award amounts total $5,281,887. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.