SBIR/STTR Research Award

A Sparse-readout Quantitative PET scanner for breast cancer therapy optimization

Award identifier 0925ac9e036f35e31347670912f6f198a65515618e7c91fe2198e080e2e637e9Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,967,422

Program and phase

STTR · Phase II

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
PET/X LLC
Proposal award date
2020-09-10
Contract end date
2022-08-31
UEI
MUL8MGG1YQU4
Solicitation number
PA19-270
Topic code
102

Research abstract

Our goal is to improve how breast cancer therapies are matched to individual breast-cancer patients with early- stage disease by providing a timely evaluation of therapy efficacy during the window of opportunity between diagnosis and surgical resection. In so doing, we aim to direct patients more quickly to effective therapies, improving outcomes, and reducing toxicities and healthcare costs from ineffective treatments. We will achieve this goal by developing a commercially viable, quantitative molecular breast imaging system (the PET/X scanner) that combines synergistically with mammography or tomosynthesis systems in breast imaging clinics. Breast cancer is the most common type of cancer found in US women and is the second leading cause of cancer death among women after lung cancer. Substantial progress has been made in treating breast cancer due to the use of targeted therapies. Unfortunately, despite the successes of targeted therapies the relapse rate in patients expressing the targets and receiving these therapies still approaches 50% for certain phenotypes. The drugs can be very costly and carry toxic side effects. Selecting from the 69 FDA approved breast cancer drugs (the most of any cancer) is challenging. A test to provide a rapid and direct measure of therapy response in each patient, or lack thereof, would greatly benefit patient care by matching patients to drugs with demonstrated success against their disease. The selection of therapies that optimize patient outcomes is a cornerstone of both the NIH precision medicine initiative and recommendations from the NCI Cancer Moonshot report. Positron emission tomography (PET) has a demonstrated ability to improve therapy selection. However, PET studies thus far using whole-body (WB) PET scanners to assess therapy response are limited to a lesion size greater than 2 cm to be quantitatively accurate. This is a challenge for breast cancer as a majority of patients present with early stage disease in which the lesions are smaller than 2 cm. To enable this treatment paradigm a PET scanner needs to be much more compact and less expensive than WB PET scanners and support correlative anatomical imaging. In addition, a high level of quantitative accuracy is needed. To meet these criteria, we will use the cost-effective dual-sided position-sensitive sparse sensor (DS-PS3) technology developed in Phase-I to build a viable PET system for the breast cancer window-of- opportunity response assessment task. The PET scanner is compatible with x-ray mammography or tomosynthesis, forming a dual-modality PET/X scanner system. We will then assess quantitative performance of this prototype with phantom images and we will acquire proof-of-concept patient images. The outcome of this Phase-2 application will be a clinic-ready prototype scanner that will be used to assess clinical feasibility and to acquire preliminary human-image data needed as evidence to warrant full commercial development and provide data for planning a clinical trial and regulatory submissions.Our goal is to improve how breast cancer therapies are matched to individual breast-cancer patients with early- stage disease by providing a timely evaluation of therapy efficacy during the window of opportunity between diagnosis and surgical resection. In so doing, we aim to direct patients more quickly to effective therapies, improving outcomes, and reduce toxicities and healthcare costs from ineffective treatments. We will achieve this goal by developing a commercially viable, quantitative molecular breast imaging system (the PET/X scanner) that combines synergistically with mammography or tomosynthesis systems in breast imaging clinics.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

4 SBIR/STTR records share this UEI (2013–2020). Reported award amounts total $2,902,459. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.