SBIR/STTR Research Award

Validation of Erythrocyte Mechanical Fragility as a biometric for performance assessment of Circulatory Support Devices

Award identifier 38956efec320a6ef8c87dc9022369bc9fa56ec90b2cabe04edc6a9802823234aAwarding agency Department of Health and Human Services · Food and Drug Administration

Award amount

$168,087

Program and phase

SBIR · Phase I

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Food and Drug Administration
Recipient company
FUNCTIONAL FLUIDICS INC.
Proposal award date
2020-09-01
Contract end date
2021-08-31
UEI
EDDMU2KMYPE3
Solicitation number
PA19-272
Topic code
FDA

Research abstract

Functional Fluidics is dedicated to commercialization of novel assays for improved blood cell health and function assessment. Cardiovascular Disease (CVD) is the leading cause of death in the United States with Heart Disease (HD) accounting for over 75% of all 840,678 deaths attributed to CVD in 2016. Mechanical Circulatory Support (MCS) devices provide cardiac and systemic support and reduce morbidity and mortality among high-risk patients. Multiple MCS device types are currently available, different in hemodynamic effects and clinical applicability, with improved efficacy and safety. MCS- induced blood damage, however, still remains a serious problem. FDA requires premarket bench testing of MCS devices to evaluate the potential for causing blood damage. Due to a lack of standardized testing “blood damage” is often assessed as either direct hemolysis or coagulopathy, ignoring rheological and biochemical impact of sublethal blood trauma. Medical device manufacturers invest up to 15% of sales into Randamp;D to address ever increasing demands on MCS performance. MCS-induced blood damage is the root cause of a wide range of adverse events that are often associated with blood thrombosis and hemolysis. Hemolysis rates of 5-8% are common, larger for ECMO, procedures like Cardiopulmonary Bypass (CPB) and for pediatric population. Development of an assay to assess sub-lethal blood damage could reduce uncertainties in development and evaluation of MCS devices and contribute to monitoring of their performance. Mechanical trauma in MCS devices in general and in ECMO in particular, arises from a combination of factors including shear stress from direct mechanical impact, turbulence, high flow rates, interaction with non-physiological surfaces, etc., with trauma different between different devices. Standardized Mechanical Fragility (MF) assay can assess induced blood trauma, including sub- hemolytic, however, the type of applied shear stress needs to be optimized to correlate to pre-existing sub-lethal RBC damage. We previously demonstrated that post LVAD implantation, RBC MF assessed using some stress application regimes, but not others, was a predictor of longer-term (4 weeks) hemolysis. Device type (HeartMate 3 and HeartWare) was also a significant predictor of RBC MF determined by some, but not all, stress regimes, with MF in turn correlated with the duration of CPB procedure. Functional Fluidics is providing the first rapid RBC MF assay, via a bench-top device using single-use cartridges. The technological innovation includes a patented MF system and means to assess RBC MF through the construction and use of MF profiles, as well as approaches for inducing functionally different types of shear stress. The final product would be a MF Testing System for better evaluation of MCS-induced damage in system development and approval process, and in the future potentially serve to monitor MCS clinical performance by assessing MCS device performance.Mechanical circulatory support (MCS) devices provide cardiac and systemic support and reduce morbidity and mortality among high-risk patients, however their use is subject to a range of complications. However, a lack of standardized testing and quantification of “blood damage” causes uncertainties in evaluation of such devices, as there are no accepted tests to assess sub-lethal blood trauma. Development of a Mechanical Fragility Testing System (MFTS) that would enable better evaluation of MCS-induced damage in device development and approval process, and in the future potentially serve to monitor MCS clinical performance by assessing device performance, patient-specific hemolysis, and hemodynamic risks.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2019–2024). Reported award amounts total $657,946. Reported amounts are not federal obligations.

Phases: Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.