SBIR/STTR Research Award

Randomized Prospective Trial of Breast Cancer Locator Guided vs. Wire Localized Partial Mastectomy for Breast Cancer

Award identifier 6a1751fda116cd0c61082db77e9fc10860b237d2caade44cd82c2e3614ae842aAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,999,999

Program and phase

SBIR · Phase II – Direct to Phase II

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
CAIRNSURGICAL, INC.
Proposal award date
2020-08-01
Contract end date
2022-07-31
UEI
KAZGK5KJJNG5
Solicitation number
PA19-273
Topic code
NCI

Research abstract

PROJECT SUMMARY/ABSTRACT:CairnSurgical, Inc., a Dartmouth spin-off company, will conduct a prospective, multicenter, 1:1 randomized, controlled trial designed to evaluate the safety and effectiveness of its Breast Cancer Locator (BCL) device in subjects with non-palpable invasive breast cancer or ductal carcinoma in situ (DCIS) under an investigational device exemption (IDE) recently approved by the FDA (Nov 2019). Subjects will be randomized to breast conserving surgery (BCS) utilizing either BCL or wire localization (WL) to guide surgery. BCL is a novel patient- specific, guidance device designed for use in breast conserving surgery (BCS) to (i) eliminate wire localization – a moderately effective, somewhat costly and certainly inconvenient procedure for patients and surgeons – and concomitantly to (ii) reduce positive margin rates (PMRs) and subsequent re-excision surgeries – a significant but unnecessary burden not only on patients but also on the cost of healthcare. In the proposed Direct to Phase II application, Cairn will (i) support 7 clinical sites as part of a multi-center pivotal randomized controlled trial, RCT, (in up to 15 centers; remaining support will derive from recently secured private investment) in 438 subjects (219 per arm) to generate evidence that PMR following BCS using the BCL is reduced relative to standard of care (WL), (ii) evaluate BCL cost-effectiveness through a healthcare economics study to generate data on use, out-comes, and savings to hospitals and payors that support market adoption, and (iii) file a de novo classification request to FDA for BCL PMR reduction marketing claims relative to WL. Based on preliminary results from a recently completed Dartmouth randomized prospective trial23 and several published RCTs of wire localization (see Table 1 in Research Strategy), we have estimated PMR in the WL arm to be 19%. The proposed study design allows definitive evaluation of superiority of BCL, with power sufficient to detect a clinically meaningful, 40% reduction in PMR, from 19% to 11.2%. In preparation for the proposed RCT, CairnSurgical has obtained IDE approval from FDA after successfully completing necessary product development and testing under design controls including, sterilization validation and biocompatibility testing. In addition, we have developed manufacturing processes to fabricate BCL devices under regulatory controls required for clinical trial use and achieve sufficient throughput scale-up by vertically integrating device fabrication, in-process inspection, sterilization and clean-room packaging capabilities. Positive margin rates associated with contemporary BCS are high (~18%-22.3%), and cause significant strains on patients and the cost of breast healthcare. Meta-analyses of the impact of surgical margins on local recurrence also confirm that negative margins have a positive prognostic effect. Thus, CairnSurgical is well positioned to develop and commercialize a potentially practice-changing approach to BCS that improves clinical outcomes for patients.Narrative:In this Direct to Phase II project, CairnSurgical will conduct a prospective, multicenter, 1:1 randomized, controlled trial to evaluate the safety and effectiveness of the Breast Cancer Locator (BCL) in subjects with non-palpable invasive breast cancer or ductal carcinoma in situ (DCIS). Subjects will be randomized to breast conserving surgery (BCS) utilizing either the BCL or wire localization (WL) to guide surgery.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

5 SBIR/STTR records share this UEI (2016–2020). Reported award amounts total $6,426,487. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.