SBIR/STTR Research Award

Degradable hydrogel for retinal tamponade (phase 2)

Award identifier f853e7913e128deffea87a8c76769b3dc878052ffc1e93c2ce5267e38f6a47e0Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$592,454

Program and phase

SBIR · Phase II

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
CAMBRIDGE POLYMER GROUP INC
Proposal award date
2020-08-01
Contract end date
2022-07-31
UEI
DKJDB8BKRGB3
Solicitation number
PA18-574
Topic code
100

Research abstract

Project Summary Retinal disorders are a common cause of debilitating vision loss. For many of these conditions, including retinal detachments and macular holes, the only treatment is surgery. The first step of all such surgeries is vitrectomy, the process of removing the vitreous gel through tiny ports in the front of the eye. Each year, 1.1 million vitrectomies are performed globally with 300,000 performed in the US alone, and in the majority of these cases a retinal tamponade is required to be left in the eye to maintain pressure on the retina and aid healing. The global retinal tamponade market was recently valued at USD $64.5 million in 2013 and is predicted to reach USD $77.5 million by 2020. The current state of the art uses either an expansile gas, or a silicone oil to exert pressure on the retina during healing (tamponade). However, neither method is ideal and therefore to address these deficiencies, this phase 2 proposal extends early work we performed on a novel hydrogel that uses two common synthetic biomedical polymers, namely a modified poly(vinyl alcohol) and poly(ethylene glycol) in a form that creates a unique hydrogel system that is very low viscosity in liquid form but then gels through crosslink formation in the eye. This formulation allows for injection through small surgical ports followed by in vivo expansion resulting in 360-degree retinal tamponade. This unique formulation will eliminate the need for post-operative patient positioning and will degrade to small molecules that are readily cleared from the eye over the period of 3-5 weeks providing a temporary tamponade force before degrading. Data from the Phase 1 supports that the resulting device will be more patient friendly with almost no refractive issues and the ability for the patient to be fully mobile and has proven degradation over 2-3 weeks with no inflammatory response, although this degradation time is also tunable. In this Phase 2 we intend to refine the formulation for improved performance and validate it within a relevant model to demonstrate efficacy.Project Narrative Retinal detachment can occur at any age, although it is more common in men, and in over the population over 40 years. State of the art treatments increasingly involve either injection of gas, or a heavy water immiscible liquid, both of which have drawbacks. Here we propose a new hydrogel based tamponade that will allow immediate return to activity and avoid long term complications or surgery by dissolving naturally over time.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

13 SBIR/STTR records share this UEI (1997–2022). Reported award amounts total $3,469,773. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation, Department of Commerce

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.