SBIR/STTR Research Award

Auto-calibrating, Air Quality Monitoring System

Award identifier 9019399c54cd9e4ad26b5d22160f6a19a2222eb9f61c0187c874a20ad92c0ca4Awarding agency Department of Health and Human Services · Centers for Disease Control and Prevention

Award amount

$541,648

Program and phase

SBIR · Phase II

Award year

2025

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Centers for Disease Control and Prevention
Recipient company
SEACOAST SCIENCE, INC.
Proposal award date
2025-09-30
Contract end date
2027-09-29
UEI
CM2UZ96ZVKS8
Solicitation number
PA23-230
Topic code
NIOSH

Research abstract

Project Summary: In 2021, chemical manufacturing industries accounted for roughly 529,000 workers, and “Extraction” accounted for 226,840 workers in the U.S. oil & gas industry. With projected growth rate of 3.8% annually in the U.S. oil and gas industries, worker exposures to harmful levels of petrochemicals are likely to increase. From 2003-2015, this industry reported 148 fatal injuries from exposures to “chemicals and chemical products.” Long-term worker exposures are not well tracked, and monitoring only occurs after a problem or illness is identified. To help address this deficiency, Seacoast proposes to develop a fully automated indoor air quality (IAQ) analyzer with speciation capability. Seacoast's analyzer, the SeaPort AQ, combines a low-cost detector, two trap-and-purge, thermal desorption collectors for signal amplification, and the separation and resolving power of gas chromatography to (1) collect and analyze air in its immediate environment, (2) provide wirelessly networked data to industrial hygienists to track workplace exposure, (3) reduce the per-sample analytical costs by automatically including calibrations without user intervention. Remote programmability will provide low per-sample costs and the ability to track chemicals around the clock. In Phase I, Seacoast assembled and demonstrated a low-cost, chromatographic analyzer to speciate benzene, toluene, ethylbenzene, and xylene (BTEX) at levels well below the OSHA 8-hr (TWA) action level (500ppb) for benzene. We demonstrated automated field-blanks, calibration, and ambient air sample collection. We integrated an oven-less gas chromatography (GC) column specifically tailored for high resolution separation of BTEX from interfering compounds common to petrochemical and related industries. The analyzer uses a high-sensitivity chemical detector for hydrocarbons, which is insensitive to humidity and CO2. Miniature valves on custom designed manifolds eliminated the need for a bulky, expensive rotary valve, allowing the analyzer to cycle through collection, purges, and re-calibrations autonomously to verify analyzer performance. The Phase I prototype exceeded our proposed goal to sample and detect benzene at 50 ppb in under 30 minutes, demonstrating collection and detection of ~5ppb of benzene in less than 30 minutes. Seacoast's air quality analyzer can finally provide hourly vapor concentration tracking data, a vast improvement over weekly or monthly data to improve exposure or pollution tracking models at a per-sample cost of ~$1. In Phase II Seacoast will complete materials and system optimization and construct robust prototypes for field testing by two experts in the two primary industries interested in air monitoring: industrial hygiene and environmental pollution mitigation. These experts will perform side-by-side comparisons of our prototype and conventional systems, and field tests at contaminated environmental sites where BTEX and other chemical pollution is known to be present at elevated concentrations in the air.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

67 SBIR/STTR records share this UEI (2004–2025). Reported award amounts total $21,050,156. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Defense, Department of Health and Human Services, Environmental Protection Agency, Department of Agriculture, National Aeronautics and Space Administration, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.