SBIR/STTR Research Award

New Photo-Acoustic Imaging Process in Fetal Monitoring to Dramatically Reduce Brain Injuries in Newborns

Award identifier b0cd3e1b851e70fec99d593074504f1df6ed08b94f14fa2d7d72d435bf3aecaaAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$149,978

Program and phase

SBIR · Phase I

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
BRIMROSE TECHNOLOGY CORP
Proposal award date
2020-07-01
Contract end date
2020-12-31
UEI
WKDYRE26KLT7
Solicitation number
PA19-272
Topic code
NICHD

Research abstract

PROJECT SUMMARY Summary The Brimrose Technology Corporation and Johns Hopkins University are forming a powerful new team to make a new instrument that has the potential to dramatically reduce a major global health problem–perinatal hypoxic- ischemic encephalopathy (HIE)–by enabling early detection during labor. HIE caused by asphyxia is a leading cause of infant fatalities as well as a source of cerebral palsy and other long-term severe neurologic impairments. The medical community has been limited in early diagnosis of HIE because current fetal heart rate monitoring has poor specificity. If identified early, HIE can be treated effectively with therapeutic hypothermia. We are proposing a fetal photoacoustic monitoring system that measures oxyhemoglobin saturation of the sagittal sinus vein draining the fetal cerebral cortex during labor. Sagittal sinus oxyhemoglobin saturation decreases to very low levels when placental gas exchange is impaired (hypoxia) and/or when fetal cerebral perfusion pressure falls (ischemia). The photoacoustic instrument transmits light through the open fontanelle or bone and into cerebral veins and tissue where ultrasound waves are generated. Using near- infrared incident light at discrete wavelengths that are absorbed preferentially by oxy- and deoxy-hemoglobin, ultrasound detected on the fetal scalp at each wavelength can estimate oxyhemoglobin saturation. Brimrose has constructed a novel ultrasound detection technology with sensitivity orders of magnitude greater than the current best-use piezo-electric sensors. This will permit the use of low-power LED light sources rather than cumbersome laser lights now employed, thereby avoiding safety goggle use and promoting greater deployment. The Hopkins team has already validated the ability of a standard photoacoustic system to accurately estimate sagittal sinus oxyhemoglobin saturation through the skull of newborn piglets. The purpose of Phase I is to demonstrate the feasibility of using safe, low power LED light sources with the new ultrasensitive ultrasound sensor to detect critically low sagittal sinus oxyhemoglobin saturation when oxygenation is manipulated. The platform will be based on in-silico simulation to optimize the acoustic and optical pathways for the skull and brain. Real-time measurements on a time scale of seconds will inform the obstetric caregiver of dynamic fluctuations of brain oxygenation during contractions. The Phase II goal is to make a miniaturized photoacoustic device prototype that can report on fetal brain oxygenation. We believe the resulting instrument will provide early detection brain HI with greater specificity and sensitivity, enabling early intervention and treatment and is potentially transferrable to a commercial model for manufacture.PROJECT NARRATIVE The Brimrose Technology Corporation and the Johns Hopkins University propose making a new instrument to potentially dramatically reduce the incidence of hypoxic-ischemic encephalopathy (HIE), which can result in mortality or lifelong disabilities. Our goal is to develop an intrapartum fetal brain monitor using photoacoustics with inexpensive, safe and clinically convenient light emitting diodes (LEDs) to noninvasively and instantaneously identify the fetus at risk for brain injury. Phase I is intended to provide a proof-of-concept using low power LED light sources and a novel ultrasensitive ultrasound detector rather than standard laser light sources and piezo-electric detectors.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

56 SBIR/STTR records share this UEI (2010–2025). Reported award amounts total $23,415,654. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, National Aeronautics and Space Administration, Department of Energy, Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.