SBIR/STTR Research Award

AST: On Target Cards for Monitoring Superfund Sites

Award identifier 02e0259be1a0faf3f52ce88060b0e8cd592445f468923b0f4fbc0cff8b1744d5Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$172,279

Program and phase

SBIR · Phase I

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Access Sensor Technologies LLC
Proposal award date
2020-05-01
Contract end date
2020-10-31
UEI
GJNAJMVMXZ13
Solicitation number
PA19-272
Topic code
NIEHS

Research abstract

Project Summary Superfund sites pose a significant risk to human health for those living nearby as they have high levels of toxic chemicals that can impact the local water and soil chemistry, leading to a myriad of diseases including kidney disease, cancer, and heart disease. Currently the Superfund site list consists of ~1400 active or proposed sites in the United States. There is an on-going need to measure remediation effectiveness and monitor toxic chemical levels over time to minimize the risk to surrounding populations. Heavy metals are common toxic chemicals found in Superfund sites. Traditional laboratory methods are capable of measuring metals but are subject to long lead times (often weeks) as well as high instrumentation and labor costs. As a result, measurements are performed infrequently and can result in unanticipated releases, putting surrounding communities at risk. Because of these problems, several point-of-need measurement technologies are used to measure heavy metals at Superfund sites, including X-Ray Fluorescence (XRF) and colorimetric test kits, but both approaches have significant limitations. The field, and Superfund sites in particular, lack simple sensors that can measure multiple toxic metals simultaneously with minimal user steps and at relevant concentration levels. The goal of this project is to develop a multiplexed water quality monitoring system for measuring toxic metals in ground and surface water at Superfund sites using Access Sensor Technologyandapos;s On-Target® card system. On-Target® cards quickly and easily measure metal concentrations in water using proprietary colorimetric reactions that generate a colored circle with a diameter proportional to concentration. While we have made significant progress with this technology, it is not applicable to Superfund site monitoring today because current detection limits are too high (ppm versus ppb) and the cards only detect a single metal, meaning users must carry a large number cards with them for complete profiling. During Phase I, we will focus on reducing the detection limits (Aim 1), creating the multiplexed assay (Aim 2), and developing first generation data visualization software while performing initial field studies (Aim 3). Samples from the Lincoln Park site (abandoned Uranium milling site) in Fremont County, Colorado will be used for testing. Our sensing system will be validated against ICP-MS or AAS for rigor. At the end of Phase I, we will have successfully created a prototype second-generation On-Target® product that enables multiplexed metal analysis at concentration levels relevant to our customers. The effort will position us for both further development during Phase II with additional analytes and penetration into the market through connections with early adopters.Project Narrative: The goal of this project is to develop a multiplexed paper-based analytical device for detection of heavy metals at the 10 ppb level in surface and ground water at Superfund sites. Our approach builds on our On-Target® card technology that detects single metals at 1 ppm levels to achieve this critical objective. After developing the system, we will test the new cards at the Lincoln Park site in Colorado.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

17 SBIR/STTR records share this UEI (2014–2025). Reported award amounts total $9,989,987. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation, Department of Commerce, Department of Agriculture

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.