Explore This Research Award in CaptureIQ
Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.
Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- RIVANNA MEDICAL, INC.
- Proposal award date
- 2020-05-01
- Contract end date
- 2022-04-30
- UEI
- S1DYEWHL6PC3
- Solicitation number
- PA19-272
- Topic code
- 102
Research abstract
PROJECT SUMMARY/ABSTRACTBone marrow and trephine biopsy (BMTB) is the gold standard for diagnosing and monitoring
hematological disorders and malignancies. Although BMTB procedures rarely cause serious adverse events,
the number of non-diagnostic biopsies should be minimized because repeated testing delays diagnosis and
treatment, consumes additional healthcare resources, and causes unnecessary patient anxiety and discomfort.
World Health Organization guidelines recommend that bone marrow biopsy cores exceed 1.5 cm in length,
however multiple clinical trials have reported that 20 – 50 % of core lengths are ≤ 1.0 cm, suggesting that these
clinical recommendations are not regularly met. This conclusion is further supported by the finding that
between 5 – 25 % of BMTB specimens are deemed non-diagnostic by pathology, often necessitating a repeat
BMTB procedure, referral for radiographic guidance of the BMTB procedure, or ultimately resulting in an
ambiguous or false negative diagnosis.The goal of this Phase II project is to finalize the design and fabrication of a clinical-trial-ready imaging
system (Accuro 3S) for real-time 3D image guidance of bone marrow trephine biopsy procedures at the
bedside. The key technological innovations of this project include: (i) the design of a miniaturized 3D
ultrasound imaging probe, (ii) the development of advanced bone-specific imaging and 3D rendering
technologies for generating volumetric reconstructions of the patientandapos;s iliac crest in real-time, and (iii) the
implementation of an image processing algorithm that automatically detects the posterior iliac crest and assists
with automated needle guidance to the target anatomy to facilitate biopsy acquisition. The intent of these
technologies is to provide an intuitive visualization of the iliac crest and to avoid difficulties associated with
ultrasound image interpretation when conducting an image-guided interventional procedure. Core technologies
will be developed and tested via extensive in vitro imaging studies of anatomically correct phantoms prior to
pre-clinical validation in a human cadaveric specimens.The impact of the proposed solution is a significant improvement in BMTB success rates and a reduced
rate of referral for radiographic guidance. These effects are expected to reduce delays in BMTB acquisition,
reduce patient exposure to ionizing radiation, and reduce costs due to the need for fewer repeat biopsies and
fewer referrals for radiographic guidance. Together, the annual costs due to referral for radiographic guidance,
repeat BMTB procedures, and costs stemming from diagnostic errors exceed $480M/yr. For these reasons,
BMTB specimen retrieval at the bedside in the hematology clinic is the preferred biopsy technique. The
technological solutions proposed in this Phase II application seek to enable improved outcomes of BMTB
procedures performed at the bedside. Finally, the total US market size for this device is estimated to be
$230M/yr, supporting the commercial viability of the proposed technology development efforts.PROJECT NARRATIVE
Bone marrow and trephine biopsy (BMTB) is the gold standard for diagnosing and monitoring hematological
disorders and malignancies. Unfortunately, a large number of BMTB specimens are deemed non-diagnostic (5
– 25%), requiring repetition of the procedure and causing additional patient discomfort, anxiety, and increased
healthcare costs. While the causes of BMTB failures are diverse, many are due to the technical difficulty of
acquiring the specimen, and many patients are referred to interventional radiology for image guidance due to
the difficulty of acquiring the specimen. The long-term goal of this project is to demonstrate a portable, low-
cost, ultrasound-based medical device that facilitates BMTB specimen acquisition, improves success rates,
lowers healthcare costs, and reduces the rate of referral for radiographic guidance.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
Research funding history
13 SBIR/STTR records share this UEI (2012–2025). Reported award amounts total $15,426,220. Reported amounts are not federal obligations.
Phases: Phase II, Phase II – Direct to Phase II, Phase I
Agencies: Department of Health and Human Services, National Science Foundation
Contractor profile
RIVANNA MEDICAL, INC.
Historical federal award activity, when published, is on that contractor profile. Matched by UEI only.
Agency intelligence
Department of Health and Human Services
NAICS intelligence
This classification comes from the contractor profile, not from the SBIR award record.
Contractor industry classification NAICS 541512
Back to SBIR/STTR Research Awards