SBIR/STTR Research Award

A Proton Tomography System for Optimization of Proton Therapy

Award identifier 8e29f354cc70fb51873eb579497ea6dafb7472beb988b4d2ae0cac2e54eb9d8cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,989,510

Program and phase

SBIR · Phase II – Direct to Phase II

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ProtonVDA LLC
Proposal award date
2020-04-01
Contract end date
2022-03-31
UEI
C3MKXMVYHKP1
Solicitation number
PA19-272
Topic code
NCI

Research abstract

Abstract Proton therapy is rapidly expanding in the United States. Currently, the calculation of proton range in proton therapy patients is based on a conversion of CT Hounsfield Units of patient tissues to proton relative stopping power. Uncertainties in this conversion necessitate larger proximal and distal planned target volume margins. These larger margins increase the dose to nearby healthy tissues, causing unwanted and avoidable toxicities. Proton computed tomography (pCT) avoids these uncertainties by directly measuring proton stopping power, and this can drastically reduce the planned target volume, thus directly reducing toxicity. Proton radiography (pRad) has the capability to accurately align the patient to the proton beam and quantify anatomical consistency and proton range in the treatment position just prior to treatment, which will lead to more consistent target coverage, yielding improved patient outcomes. Clinical proton imaging systems must provide pCT as well as pRad capability. This project aims to achieve the advances that will ensure the full functionality of proton imaging in a clinical environment and demonstrate a proton imaging system with a path to FDA clearance. These key improvements in proton therapy are an essential requirement as the field of radiation oncology moves toward hypofractionation (higher dose treatments given in fewer fractions). ProtonVDA (https://www.protonvda.com/), with a recent Phase II SBIR grant, has demonstrated the first fully functional prototype of a system able to take and promptly display accurate pRad images with clinical proton pencil beam scanning systems using very low intensity to analyze individual protons. While a fully functional pCT system does not yet exist, this project will involve co-investigators from Loma Linda University with extensive experience with a preclinical pCT system. ProtonVDA’s technology will be used to develop a fully functional pCT prototype. Whereas pRad uses a single beam direction, pCT requires a complete set of angles spanning at least 180 degrees in the object reference frame. This can be achieved either with a fixed pCT system and proton beam while rotating the object or with a fixed object while rotating the pCT system along with the proton beam. In both cases, precise information on any mechanical movements within the beam delivery, imaging, and object reference frames is essential, because effects from axis misalignment or mechanical sagging can significantly degrade image quality. Therefore, the prototype will incorporate an optical tracking system to measure and correct for these movements. Project collaborators from Provision (https://provisionhealthcare.com/) have previously demonstrated the use of optical tracking for patient positioning. After development of the pCT system, tests using pCT-planned proton beams applied to phantoms containing dosimetric films will verify the clinically relevant accuracy of pCT.Narrative Proton radiation therapy treats cancer while potentially sparing large amounts of normal tissue from low to intermediate radiation dose and avoiding organs at risk. Currently, uncertainties in treatment planning necessitate larger proximal and distal planned target volume margins. Proton computed tomography is a method of directly measuring proton stopping power, and this can drastically reduce the planned target volume, thus directly reducing toxicity.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2015–2020). Reported award amounts total $5,244,842. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.