SBIR/STTR Research Award

High Spatial Resolution Detectors for Single Crystal Diffractometers

Award identifier baa17499a929a1efb5d5940d2bb5e331b244e8e82bddc696605ad8586989756cAwarding agency Department of Energy

Award amount

$200,000

Program and phase

SBIR · Phase I

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
PROPORTIONAL TECHNOLOGIES, INC.
Proposal award date
2020-02-18
Contract end date
2021-02-17
UEI
TAPPXED88F63
Solicitation number
DE-FOA-0002145
Topic code
18b

Research abstract

Proportional Technologies, Inc. PTI) proposes the development of a neutron detector based on boron-coated rectangular channels, to satisfy the requirements of single crystal diffractometers, like MaNDi and TOPAZ at the SNS. Detectors for these instruments require high spatial resolution on the order of 300-600 μm, efficiencies greater than 60% at 1Å, gamma rejection on the order of 10-6 or better, and count rate capability of 100 kcps. Additionally, the detectors should allow near 4π coverage with minimal dead area, and little parallax. PTI will develop a boron-coated structure that satisfies the above requirements in a close-packed array of rectangular cells, sealed inside a single thin Al housing. Each cell will be fabricated by squashing a round boron-coated straw BCS) into a rectangular shape, lined on all 4 sides with enriched boron carbide 10B4C). Cell dimensions will be 0.5 mm  2.5 mm  150 mm. A 3006 array of cells will form a 150150 mm2 detector panel. Resistive wires tensioned at the center of each cell will be read out individually, in order to decode the cell ID. Charge division will be used to decode the event position along the length of the wire. The array will be oriented such that neutrons are incident at an angle θ=11.3. This angle, equal to the arctangent of the cell dimensions ratio, θ=arctan0.5/2.5), ensures that neutrons always traverse one long side of the cell they hit. Thus, they go through the 2 coating layers of that side at a very steep angle. The detection efficiency of a 6 layer-deep array, will reach 61% for 1-Å neutrons. The array will have a gamma discrimination on the order of 10-7, previously demonstrated in BCS detectors, and fast signals of 100 ns, for a count rate capability of 1000 kHz. If our proposed SBIR project objectives meet the challenge, society will benefit from inexpensive, high sensitivity panels for use in Single Crystal Spectrometers at SNS as well as around the world. The increased speed of completion and quality of crystal studies is expected to provide great public benefit in diverse fields ranging from superconductivity to effective development of new drugs for cancer treatment.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

55 SBIR/STTR records share this UEI (1994–2023). Reported award amounts total $25,350,343. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Energy, Department of Defense, National Science Foundation

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.