SBIR/STTR Research Award

Development of a miniaturized, single-port automated insulin delivery system utilizing a glucose sensing catheter, ultra-concentrated insulin, and an optimized control algorithm

Award identifier 263e5723cfc49abb1258b1dd234efeb824c96782e40c4ced93b02a6cd05928aaAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$299,555

Program and phase

SBIR · Phase I

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Pacific Diabetes Technologies
Proposal award date
2019-09-20
Contract end date
2020-08-31
UEI
LVNAHGVG6DV4
Solicitation number
DK18-022
Topic code
200

Research abstract

ABSTRACT SignificanceThere are overmillion people with insulin treated diabetes in the United States who represent a disproportionately large share of the $B in direct medical costs attributable to diabetesThe use of continuous glucose monitoringCGMhas been shown to reduce HbA c levelsa proven predictor of health outcomes within this populationwith the greatest improvement achieved when CGM is coupled with continuous subcutaneous insulin infusionCSIIThe recent convergence of CGM and insulin pumps has enabled the first generation of automated insulin deliveryAIDsystemspromising even better glycemic control for insulin treated diabetesHowevercurrent AID systems are complexcumbersomeand expensive for the patient because they require multiple devices to be worn on the bodya glucose sensoran insulin pumpand an insulin delivery catheterWe have developed a glucose sensing catheter that reduces the number of subcutaneous components from two to onesignificantly reducing the size and complexity of these systemsBy integrating the sensing catheter into a patch pumpwe will further simplify the system by reducing the footprintand enabling the first fully integrated single component AID systemResulting reductions in system sizecomplexityand cost will increase adoption rates for AIDhelping improve compliancelower HbA c levelsand improve health outcomes among people with typediabetesPreliminary DataWe have demonstrated glucose sensing can be performed at the site of insulin deliveryHoweverwe have discovered that there is a glucose measurement artifact that occurs immediately after dispensing liquidinsulin or salinefrom the cannulalikely caused by dilution of the surrounding interstitial fluidPreliminary data suggest the magnitude of the artifact is related to the volume of the bolusSpecific AimsThis proposal represents the first phase of an effort to integrate the dual use cannula with a miniaturized patch pump and an AID algorithmtaking advantage of a novel concentrated insulin to reduce CGM artifact sizeIn Specific Aimwe will reduce the impact of the dilution artifact through the use of ultraconcentrated insulinWe will characterize the impact of the artifact using smaller boluses of Uinsulin in a swine studyIn Specific Aimwe will create a calibration algorithm based on a Kalman filter and a predictive model of future sensor values to further mitigate the dilution artifactIn Specific Aimwe will integrate the kinetics of the Uinsulin into a model predictive controlMPCAID algorithm developed by Oregon Health andampScience UniversityOHSUand optimize the algorithm toincorporate a model of the kinetics of the Thermalin insulin andeliminate any remaining dilution artifact that may still be presentWe will evaluate the performance of the new calibration algorithm on the data collected in Aimas well is in other human data that we have collected with the glucose sensing catheterThe MPC algorithm will be evaluated in silico using the OHSU virtual patient population in preparation for full integration into the Thermalin StampPump in phaseof this proposalIn summarythis collaborative effort between PDTOHSUand Thermalin brings together the only published amperometric glucose sensing catheter with a fault tolerant AID algorithm and the only rapidconcentrated insulinIn shortwe are the only team currently capable of providing this novel solution for a unified automated insulin delivery device NARRATIVEIn this projecta combined insulin delivering and continuous glucose monitoringCGMcannula will be integrated with a miniaturized patch pump from Thermalin and an automated insulin dosingAIDalgorithm from Oregon Health andampScience UniversityIn PhaseCGM performance will be improved through use of ultraconcentrated insulin from Thermalin to reduce bolus size and through the use of predictive algorithms that are optimized to accommodate a dilution artifact following large bolusesAn AID algorithm will be updated to work with Thermalin Uinsulin and optimized to eliminate the impact of any remaining dilution artifact

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

4 SBIR/STTR records share this UEI (2013–2021). Reported award amounts total $2,244,379. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.