SBIR/STTR Research Award

A Next-Generation, Efficient, Fully Automated, High-Definition 3D Patient Treatment Verification System for Stereotactic Radiation Therapy,Radiosurgery and Particle Therapy

Award identifier e0f3799a7c8dbe8af5cbcce11a00a84cc0b3e818ead602e4d57fb65e7cda6a2eAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$300,000

Program and phase

SBIR · Phase I

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MGS RESEARCH INCORPORATED
Proposal award date
2019-09-17
Contract end date
2021-02-28
UEI
Not reported
Solicitation number
PA18-574
Topic code
101

Research abstract

The GoalTo improve patient safety and outcomes for all modalities of external beam radiation therapy in a cost effective manner by using a new type of HDD pre treatment Patient Specific Quality AssurancePSQAProduct to be Developed by the end of Phase IIThe CrystalBallSystemwill consist of a fully robotized fast laser CT of low cost reusable radiochromic polymer gel dosimetersIt will detect and correct all significant errors accumulated during treatment planning delivery that would likely be missed by existing QA toolsExisting Paradigms and Clinical Practices Being Challengedcurrent emphasis on device performance QA rather than process QAinadequate density of data sampling in measured QA dose distributions inDHealth Relatedness of the ProjectTheCrystalBallwill be able topredict the futuresuccess or failure of a patient s radiotherapy treatmentRoutine use of this product will lower cancer care costs associated with avoidable recurrences and complications that lead to costly readmissionsdisabilitiesand premature deathCritical Barrier to Progress inD Polymer Gel Dosimetry Being AddressedPersistent lack of a commercial polymer gel dosimetry package that is not only accurate but also cost effective and time efficientPhase I Specific AimsFeasibility of Critical Technological Innovationsnovel reusable radiochromic polymer gel dosimeter with instant dose response and stable signalthermally reversible and resettable overnightsuitable for cost effective daily PSQA usageAlso optically chemically compatible with selectedD printing materialsnovel design of a cost effectivefast laser CT scanner for imagingD dose distributions in polymer gel dosimetersnovelD autocalibration algorithm based on dose response modelingenabling a time efficient single scan PSQA protocolnovel algorithm for autosegmentation of multi PTV dose distribution data and for autogeneration of QA reports for individual PTVswith application to single isocenter VMAT treatment of multiple brain metastasesnovel software interface for HDD QA analysis with detailedanalysis options triggered only by suboptimalD gamma passing rates and or other global metricsAimsandwill be tested at a leading radiation oncology department under ain kind subcontractOutline of Likely Phase II Specific AimsContinuation of Phase I Research and Product Developmentnovel fully robotized system for batch processing all exposed CrystalBallsfor daily PSQAlaser CTscanningQA reportsannealing andampresetting overnightnovel designs of phantoms protocols software for HDD PSQA of SRSSBRTVMATIGRTMR linacand proton beam therapyincluding motion deformation control and gatingnovel design ofD printed anthropomorphic phantoms compatible with the new polymer gelsnovel design of phantoms protocols software for HDD machine QAfor MLCstablegantrycollimatoroutputnovel software for autogeneration of corrections to treatment plansnovel software for correlating HDD QA results with log filesin order to identify likely root causes of detected errors This project will improve radiotherapy and radiosurgery outcomes and patient safety while substantially lowering cancer care costs associated with avoidable recurrences and complications that lead to costly readmissionsdisabilitiesand premature deathwith all associated social costsThe product to be developed by the end of Phase II will routinely and cost effectively detect and correctprior to patient treatmentcommon errors that would be accumulated over the entire treatment planning and delivery processerrors that are normally hidden from existing radiation measurement systems and quality assurance protocols due to inadequate sampling of radiation dose data and patient positioning in bothD space and timeThe primary and unique advantage of the proposed newCrystal Ballsystem is its ability to detectprior to patient treatment and in a cost effective and time efficient mannerany clinically significant cumulative errors originating anywhere during the planning and delivery process and located anywhere in the treated volume of tissue

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.