SBIR/STTR Research Award

Drug-eluting Brachytherapy Implants for Chemo-radiation Therapy

Award identifier 4fa2b737bb1c7f9a4798f938b55c9b9e0e48bcacf2c2e70b08f78a77b72184c2Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,000,000

Program and phase

STTR · Phase II

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TheraNano LLC
Proposal award date
2019-09-13
Contract end date
2021-08-31
UEI
JCU5WSZNSTF3
Solicitation number
PA18-575
Topic code
102

Research abstract

Theranano LLC in collaboration with internationally renowned prostate brachytherapy clinicians at Brigham and Womens Hospital and Dana Farber Cancer Institute and biomaterials experts at Northeastern University have developed an innovative combinatorial treatment strategy of Local ChemoRadiation Therapy (LCRT) using a modified brachytherapy spacer platform in the form of a INCeRT (ImplaNts for ChemoRadiation Therapy) spacer loaded with Docetaxel (DTX) to locally radiosensitize the prostate, enabling a synergistic cure with the use of lower radiation doses, thereby leading to less rectal radiation toxicity and minimal chemotherapeutic systemic side effects.Extensive results have demonstrated the efficacy and safety of the technology: (i) As monotherapy, in PC3 tumored mice, therapeutic doses of DTX can be delivered using intratumoral INCeRT spacers that lead to complete tumor suppression and disease free survival in 90% of animals. (ii) DTX-loaded INCeRT spacers show sustained synergistic radiosensitization. (iii) For combined LCRT, sustained DTX release prolongs the tumor suppression in irradiated mice. (iv) Toxicity as assessed by gross weight, and visual observation, is greatly reduced compared with IV administration of equivalent doses of DTX. These results have demonstrated the validity and feasibility of LCRT using INCeRT spacers.The Phase I STTR project demonstrated the feasibility of a solvent free hot-melt extrusion process of fabrication of InCeRT DTX spacers thus providing proof-of-principle of reproducible scale-up of manufacturing of INCeRT spacers. The HME spacers fabricated possessed all the desired material and drug characteristics, as well as in vitro release, PrCa model efficacy and toxicity profiles, achieving all the aims of the project. The Phase I project met and exceeded all its aims. In this Phase II STTR project Theranano will partner with outstanding collaborators to carry out IND-enabling GLP level manufacture and pre-clinical animal studies through the following aims: Specific Aim 1: Fabricate GLP quality InCeRT-DTX brachytherapy spacer implants GLP level manufacture of InCeRT-DTX implants will be carried out. The GLP implants will be thoroughly characterized for their physico-chemical properties. Specific Aim 2: Non-GLP therapeutic efficacy of INCeRT spacers in clinically relevant PCa mice models. The implant spacers fabricated in SA1 will be tested for release and therapeutic efficacy in PC3 cells and tumor models to ensure their bioactivity. Specific Aim 3: IND-enabling GLP pharmacokinetics and toxicity evaluation of INCeRT implants with brachytherapy in canine models. GLP level animal studies in canine models will be carried out for demonstrating the safety of the InCeRT-DTX implants in conjunction with I125 brachytherapy seeds. Specific Aim 4: Submission of FDA IND application An FDA IND application will be submitted and planning for a Phase I clinical trial will be initiated.PROJECTNARRATIVE TITLE: Drug-eluting Brachytherapy Implants for Chemo-radiation Therapy This STTR phase II project seeks to translate drug-eluting brachytherapy implants for Local Chemo-Radiation Therapy (LCRT) as a new modality of prostate cancer treatment. LCRT combines radiation therapy with chemotherapy delivered locally to the prostate, utilizing drug releasing spacers similar to those currently used in brachytherapy, to boost the overall treatment efficiency while greatly reducing toxic side effects. The treatment has the potential to improve the lives of all of the thousands of men with localized prostate cancer who are treated each year with radiation therapy.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

4 SBIR/STTR records share this UEI (2017–2019). Reported award amounts total $2,750,211. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.