SBIR/STTR Research Award

Artificial Urethral Sphincter for Control of Urinary Incontinence in Pediatric Patients

Award identifier d9df5497efdeeaab80df95a78ba3d55320e59ed1134c9072c589343cd94df665Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$224,771

Program and phase

SBIR · Phase I

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
FANNIN PARTNERS LLC
Proposal award date
2019-09-13
Contract end date
2020-09-12
UEI
DAHAYJEBV8K1
Solicitation number
PA18-574
Topic code
400

Research abstract

PROJECT SUMMARY SignificanceEach year in the U Sbetweenandchildren are born with spina bifidaand nearly all of these patients develop neurogenic bladderUrinary incontinence in neurogenic bladder patients often is a result of inadequate bladder outletsphincter resistance and can lead to a significant negative impact on these patientsquality of lifeincluding emotional distress and other health issues related to the urinary leakageAt present there is no idealnon invasive method for urinary drainage and continence in childrenThere is a need for a device that more effectively addresses urinary incontinence in pediatric patients with neurogenic bladderInnovationThe SecUrine device is a soft silicone urinary valve that prevents urinary incontinence at the bladder outlet level that can be used in adults and childrenThis temporarynon surgical artificial urinary sphincter is deployed in the urethra at the bladder neck via urethral catheterization and removed afterdays with the use of a balloon urethral catheterThe valve allows for the passage of a catheter into the bladder via the urethra which allows for CIC to drain the bladderAdditionallythe valve will open when the pressure in the bladder reaches a threshold value serving as a safety mechanism that avoids high bladder pressures and subsequent kidney damageTo prevent encrustation of the devicea silicone material impregnated with an anti fouling agent is used to improve device longevity and reduce infection riskApproachIn this SBIR Phase I projectFannin Innovation Studio will optimize the prototype device design and test it in benchtop and animal models of the urinary tractThe Specific Aims of this project areDevelop the design and manufacturing methodand conduct in vitro feasibility tests for the SecUrine artificial urinary sphincter by exploring multiple concepts and implantable polymer candidatesThis includes refining product requirements for implant and delivery and removal systemevaluating implantable polymer elastomer candidates for urinary valvesideation and design of delivery and retrieval devicesand screening of material samples for antimicrobial efficacyConduct functional testing of the SecUrine device in a benchtop model and an acute porcine modelThis includes in vitro test bed developmentbench testing and final design selectionfabrication of final designs for animal testingand the in vivo testing of device insertioncatheterization voidingand device removal in a pig modelThe outcome of Phase I will be a fully functional prototype for an implantable valve that prevents urinary leakage and maintains safe bladder pressuresThe SecUrine device provides a non invasive solution to pediatric neurogenic bladder patients that is compatible with their urinary tract anatomy and allows them to avoid surgical procedures during their pediatric growth years PROJECT NARRATIVE Urinary incontinence is a major problem in pediatric patients with neurogenic bladderThe current standard of care is a combination of oxybutynina drug that reduces bladder muscle overactivityand intermittent catheterization approximatelytimes a dayHoweververy oftenthere is still leakage of urine between catheterizations which leads to significant emotional distress and other health related issuesIn the proposed solutiona soft silicone valve is insertednon invasivelyeverydaysinto the bladder neck to prevent urine leakageThe patient may still use intermittent catheterization as a method of voidingbut there will be no leakage between voids

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

15 SBIR/STTR records share this UEI (2017–2025). Reported award amounts total $10,167,978. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.