SBIR/STTR Research Award

Novel Saliva-based Renal Function Test Platform

Award identifier bbfa177741813b43181b9e2d8d97a2423eeb2beb0b2571e3fb9e59c2dd9de5abAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,488,606

Program and phase

SBIR · Phase II

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
INTELLIGENT OPTICAL SYSTEMS, INC.
Proposal award date
2019-07-01
Contract end date
2021-08-31
UEI
NLDHG92SMX37
Solicitation number
PAR17-034
Topic code
400

Research abstract

Project Summary Chronic Kidney Disease (CKD) affects millions of people worldwide, including 20 million adults and children in the USA. Timely detection of kidney function deterioration can improve management of CKD, including in kidney transplanted recipients. Without a blood draw, an acute kidney injury (AKI) event or a transplant rejection could remain unrecognized for extended periods of time, leading to irreversible loss of kidney function and structure. Novel patient-friendly methods of kidney function measurement with high levels of precision and reproducibility are urgently needed to ensure more frequent and reliable monitoring in the home and for point-of-care screening. Currently, invasive phlebotomy followed by laborious blood specimen processing and reporting are the only way to measure the three major kidney filtration markers: serum creatinine, urea, and cystatin C. However, saliva has been proven to mirror blood biomarker levels. Limited preliminary data suggest that salivary creatinine and urea levels correlate with those in serum in CKD patients. Measurable levels of cystatin C have been assayed in saliva without being affected by periodontal disease. Based on these findings, Intelligent Optical Systems (IOS), in collaboration with the University of California (UC) Irvine and UC San Francisco, plans to develop (Phase I, 12 months) a novel means of detecting creatinine, cystatin C, and urea in saliva, using a highly sensitive and selective enzyme-based lateral flow assay (ELF assay). In this novel, compact, single-step, enzymatic multiplexed assay, highly fluorescent dyes yield reliable quantitative measurements on a portable analyzer. The innovatively developed methods will be subsequently (Fast-Track) validated in 200 CKD patients from UCI nephrology and transplant clinics (Phase II, 24 months). The proposed development builds on extensive IOS expertise in complex assay development, using saliva matrix that has been successfully validated in clinics for bone metabolism markers and rapid testing for drug of abuse. In Phase I we will demonstrate the feasibility of recording reproducible and sensitive measurements of salivary creatinine, cystatin C, and urea, using spiked and laboratory tested human saliva samples obtained from BioreclamationIVT. Assay specification, sensitivity LOD, specificity, and stability will be reported by the end of Phase I in accordance with IOS-established protocols for salivary assay development and optimization. Building on a successful Phase I demonstration of an ELF assay, and validating the results against the predetermined milestone criteria, we will then conduct the clinical validation in Phase II, testing saliva measurements against blood levels in 200 human subjects with CKD – including 50 kidney transplant recipients – with a broad range of GFR of 10-60 mL/min/1.73 m2 BSA. Our proposed Fast-Track design is efficient, feasible, and innovative, and has a high likelihood of sustained powerful influence and immediate clinical applicability. The availability of non-invasive, point-of-care, multiplex measures of kidney function would have a dramatic impact on the care and monitoring of patients with CKD, particularly in remote locations.Project Narrative Intelligent Optical Systems, in collaboration with the University of California Irvine Nephrology and transplant Centers, proposes to develop a novel rapid technique for measuring three kidney function markers in saliva. The device will be portable for rapid bedside measurement of saliva samples acquired noninvasively from patients in point-of-care and home settings, and for rapid screening. The multiplexed measurements of the target markers will not only be a reliable and reproducible measure of kidney filtration function, but will also be an early predictor of CKD progression or acute worsening of kidney function in transplanted patients.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

264 SBIR/STTR records share this UEI (1998–2025). Reported award amounts total $77,140,779. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Health and Human Services, National Aeronautics and Space Administration, Department of Energy, Environmental Protection Agency, Department of Agriculture

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.