SBIR/STTR Research Award

Goldmann Contact Tonometry with Optimized Error Correction

Award identifier 95d9378ab6d58f5bb27eb1d5b3a4b6409219e145c50ae827f355ec6495d18954Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,124,954

Program and phase

SBIR · Phase II

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
CATS TONOMETER LLC
Proposal award date
2019-07-01
Contract end date
2022-06-30
UEI
T55ZL6UFXXX9
Solicitation number
PA18-573
Topic code
NEI

Research abstract

Intuor Technologies, LLC - Project Summary Goldmann Contact Tonometry with Optimized Error Correction Intraocular pressure (IOP) measurement is a very important criteria used to assess visual acuity when eye care professionals are diagnosing, treating, and managing potential glaucoma patients. Goldman tonometry (GAT) IOP is recognized as the “gold standard”, but GAT IOP measurements errors have been identified. Phase I results indicated GAT IOP errors were over +/-2mmHg and up to +/-10mmHg in most patients. Those errors result in 50% of the population at risk for vision loss or over treatment. The GAT prism cannot accurately measure IOP due to corneal variabilities such as thicknesses, rigidity curvature, and tear film. Based on Phase I results, Intuor achieved FDA clearance on the CATS reusable prism. The Phase I results also showed CATS Prism improved IOP accuracy a 94% over GAT prism errors. The Phase II work will further the innovation and speed commercialization of CATS prism via ergonomic and manufacturing innovations. Addressing demonstrated market demand, Intuorandapos;s Phase II project will transfer and verify the CATS technology to an injection molded disposable prism with an enhanced ergonomic design. A disposable prism solves many current challenges presented by reusable prisms. The alcohol cleaning methodology for reusable GAT prisms currently used in practice resents a potential health hazard from cross-patient contamination and infection due to improper cleaning techniques. Additionally, reusable prisms are often replaced well past their serviceable life. Intuor plans to eliminate these health hazard by producing a competitively priced disposable prism via one step, injection molding. CATS disposable prism development will lead to a cost- effective prism greatly reducing potential cleaning agent corneal toxicity and infection potential. To achieve the tight tolerances and manufacturing capability requires innovative, iterative designs and multiple injection cycles. The second aspect of the Phase II is a clinically rigorous demonstration of CATS improved IOP accuracy via two distinct clinical studies for ineffectively served populations (pediatric and refractive surgery patients), so clinicians can confidently measure IOP to properly manage these populations. These two groups combined represent 30% of the general population. The clinical trial results will be leveraged into expanding the CATSandapos; currently FDA cleared indications for use with additional claims increasing marketability and utilization across all segments. If successful, these developments described above will eliminate the limitations of the IOP test while preserving its advantages of acceptance, simplicity, and cost.Intuor Technologies, LLC – Project Narrative Goldmann Contact Tonometry with Optimized Error Correction Intuor will build on the successful Phase I grant to engineer, test, and perform a clinical trial on a CATS disposable prism that addresses all known Goldmann Tonometer prism (GAT) intraocular eye pressure (IOP) errors. These GAT errors result in inaccurate IOP readings that are a critical barrier to providing earlier diagnosis and management of glaucoma, as well as treatment of currently ineffectively served populations, such as pediatric and LASIK patients. If successful, advancements from Phase II will enable the standard IOP measurement to realize its full potential as an accurate, cost-effective, safe, and non-invasive tool for the diagnosis and management of glaucoma.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.