SBIR/STTR Research Award

Development of a novel clinical assay for measuring everolimus levels

Award identifier f754fba55c02118b0e1af6ed867bc50885737d9d33479ec8a20986a0a4bf1dd9Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,110,514

Program and phase

SBIR · Phase II – Direct to Phase II

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
AFFINERGY, LLC
Proposal award date
2019-05-21
Contract end date
2022-04-30
UEI
YJQ6K1QMS488
Solicitation number
PA18-574
Topic code
NIAID

Research abstract

SUMMARY/ABSTRACT In 2017 nearly 35,000 solid organ transplants were performed in the United States, an increase of 27% over the past ten years. Organ transplantation requires lifelong immunosuppression to prevent rejection of the transplant. Many new classes of drugs have been developed to combat the side effects and interactions common to immunosuppressants, with several agents (sirolimus, everolimus, and belatacept) gaining momentum in immunosuppressive treatment regimens. Many of the immunosuppressants, including everolimus (EVR), have a narrow therapeutic range and warrant therapeutic drug monitoring (TDM), as sub-therapeutic levels increase the risk for rejection while supra-therapeutic levels are associated with significant toxicity. In addition to significant pharmacokinetic variability, andgt;25% of patients are non-adherent to their immunosuppressant regimen, leading to unnecessarily high graft failure rates and a staggering financial burden on the healthcare system. Current methods to measure EVR are costly and time consuming, or fraught with metabolite interference and significant variability. Because transplant recipients must take their immunosuppressant for the life of the graft, there is an urgent and unmet need to develop a simple, cost effective, and precise way of monitoring EVR levels.Liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) is the current gold standard for EVR TDM, but it is costly, requires extensive technical expertise, has long turnaround times and low throughput, and large inter-lab variations (i.e. poor harmonization). Immunoassays represent a more affordable, high-throughput, and simple platform for TDM. However, the only immunoassay on the market is a competitive assay that indirectly measures EVR in patient samples and suffers from cross-reactivity with metabolites and a related immunosuppressant. Additionally, use of this approved immunoassay on different analyzer platforms and differences in calibration methods between labs has led to inconsistencies and large variability from lab to lab. Because supra-therapeutic dosing of EVR is associated with adverse events and patient discontinuation of EVR, accurate monitoring of EVR is critical for rapid detection of patient non-compliance and preservation of the graft. Affinergy has developed highly sensitive capture and detection reagents for a one-step sandwich-type assay that will enable frequent, simple, and affordable monitoring of EVR in whole blood. In this Direct- to-Phase II application, we will optimize our previously identified capture and detection reagents and adapt them to an existing automated clinical analyzer platform used in clinical chemistry labs. At the conclusion of this application, we expect to have a fully optimized assay for EVR TDM.PROJECT NARRATIVE Organ transplant recipients receive immunosuppressants to prevent graft rejection, but many of these drugs have a narrow therapeutic index and require routine drug monitoring to ensure patients are receiving an appropriate dose and to monitor patient compliance. Current technologies to measure the immunosuppressant everolimus are either costly, time-consuming, and require highly skilled operators, or are plagued by cross- reactivity issues that overestimate the amount of everolimus present. In this application, we propose to further develop a novel assay to facilitate rapid and affordable measurement of everolimus in whole blood.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

75 SBIR/STTR records share this UEI (2005–2023). Reported award amounts total $59,804,968. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.