SBIR/STTR Research Award

A reliable and accurate miniaturized wireless electrochemical glucose sensing solution for closed-loop diabetes management

Award identifier 9f13c2431063d2d8123a5826a20e27579ef1caf473fa7ac2310e1d9c8074ed20Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$250,000

Program and phase

SBIR · Phase I

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Integrated Medical Sensors
Proposal award date
2019-05-20
Contract end date
2020-05-19
UEI
HJ46NHNMRF13
Solicitation number
PA18-574
Topic code
200

Research abstract

PROJECT SUMMARY The long termgoal of this project is to develop a low costuser friendly glucose sensing solution with multi mode sensing reliability to enable the use of closed loop insulin delivery safely and reliably in an artificial pancreasThe system has the potential for fast sensor kinetics owing to small size and thin and flexible profile leading to better integration with the surrounding tissue and local vascularizationThis can enable automatic closed loop glucose control without meal announcements and carbohydrate countingIMS has developed a novelminiaturizedsmaller than half a sesame seedcompletely wirelessand extremely low cost glucose sensor that consists solely of a semiconductor deviceThis device can sense glucose owing to a novel microelectronics design and an integrated on chip electrochemical sensorThis device is injected in subcutaneous tissue using a proprietary inserter and wirelessly communicates the glucose data to an external transmitter device which relays it to a smartphone to enable data visualization and cloud based data handling to provide real time feedbackWith help of CaltechNIHand NSF fundingwe have e demonstrated sensor functionality in vitroin ratsandmost recently in porcine model for more thanmonthOur results indicate the sensor is very accurateMARDfor andltmg dl which is the most important rangeand can work for longer timemonthsafter some chemistry improvements i euse of catalase to minimize effect of peroxide denaturing of glucose oxidaseThereforeourobjective in this proposal is to develop a version of our wireless glucose sensing platform that can measure glucose usingtwo different sensing modalitiese gdifferential oxygen measurementand amperometric peroxide measurementtoincrease the reliability of the readoutThe use of these two modes extend the performance window of the implant by taking advantage of sensitive peroxide detection along with more stable differential oxygen sensingThe sensing platform will be tested in porcine model as it matches well with human skin and metabolismThis research issignificant as it will enable first factory calibrateduser insertable and removablewireless CGM sensor that can work for long timemonthsprovide reliability of redundant glucose sensingand fast response that can all enable safe and accurate closed loop glucose control in an artificial pancreasThe projectteamincludes original inventors of the core technology from CaltechDrNazariDrRahmanMrSencanseasoned and respected researcher in Glucose sensor technologyBill Van Antwerpexperimental surgery and biomaterials expertDrJonathan Lakey of UC Irvineand commercialization expertMrPeter Rule from MiniMedTherasenseand OptiScanThe company is working within IVD Technologies Incan ISO certifiedFDA registered biotechnology company under a facilities rental agreement Project Narrative Diabetes affects more thanmillion people worldwide more thanmillion of whom live in the USCGM is the technology of choice for diabetes managementby itself as well as in conjunction with insulin delivery devicespumpspensHoweverboth transcutaneousdue to tissue irritationCGM devices and recently approved wireless CGM devicesdue to large sizesuffer from significantly large blood ISF delay and adverse foreign body reactionIn this proposalwe intend to design a wireless glucose sensor that can minimize foreign body response due to its small size and thin profile that integrates better with surrounding tissueThis can result in a sensor that provides faster kinetics as compared to bigger or wired devicesand can work for long timemonthsIMS has proven the feasibility of a basic wireless sensor in lab benchandgtyearand in pigs for more thanmonthOur main goal in this proposal is to design a better version of the implant that extends the IMS sensor to enable it to measure glucose reliably by using two sensing modalitieswith longer lifetime due to superior electrochemistryThe above mentioned advantages alongwith with low cost and potentially fast kinetics can enable the use of artificial pancreas for a diverse range of patients for whom glycemic control otherwise is difficult leading to both morbidity and mortality

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

11 SBIR/STTR records share this UEI (2016–2025). Reported award amounts total $4,976,700. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.