SBIR/STTR Research Award

The Bumps: A Device for Rapid, Non-Invasive Quantification of Touch Sensation

Award identifier 1e5195479c229968bbd4eac42234762845ad383ea427178e2627b3f75ab4bf23Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,858,400

Program and phase

STTR · Phase II

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Neuro Devices, Inc.
Proposal award date
2019-04-11
Contract end date
2021-03-31
UEI
CZ8UKQEH8MX8
Solicitation number
PA18-575
Topic code
100

Research abstract

The Bumps: A Device for Rapid, Non-Invasive Quantification of Touch Sensation Abstract !Our proposal describes an elegant device called the Bumps that quantifies finger pad touch sensation at low micron levels. The objectives are to diagnose peripheral neuropathy near its onset, when the possibility for reversal is highest, and to monitor either progression or reversal of neuropathy during treatment. Early discovery of functionally impaired touch provides a better chance to halt or reverse neuropathy than later discovery by tests that rely on the effects of nerve degeneration for diagnosis.The Bumps is a deceivingly simple, coat pocket size device without power or moving parts that quantifies finger pad touch in 5-7 minutes. The device is a smooth surface marked into checkerboard-like squares. Each square contains five colored circles. One circle in each square contains a tiny coin-shaped particle (a bump). Subjects search the circles of each square with the finger pad in search of the one circle that contains a bump. Bump height is different in each square. The test is objective because the subject must locate a bump from among several possible locations. The unique feature of the Bumps is that the subject continuously uses the very motor and sensory nerves suspected of being neuropathic to control the search with the finger pad and monitor the sensory input. Other tests of touch sensation are subjective. For example, an examiner touches the skin with a von Frey monofilament or probe, then asks the subject if they felt the probe, yes or no, felt or not felt.In Phase I, we demonstrated feasibility of the device. In Phase II, we tested healthy control subjects and subjects with peripheral neuropathy with the original device to start a database with mean control thresholds for sex and age ± std. dev. and cutoff values for customers to use as standards to compare with results from their patients. At the onset of Phase II, we worked with four different companies each using their special techniques as they attempted (unsuccessfully) to construct a Bumps device with the precision required at nanometer levels. After an extensive search, we found 10X Technology LLC, an Illinois company that is capable of constructing a master mold that will be used in Phase IIB to produce the final Bumps product in larger quantities at a reasonable price for providers in clinics, hospitals and other health care settings.Phase IIB goals are: 1) Construct a market-ready Bumps device. 2) Compare the results obtained from the new Bumps device with results from the original ground-glass prototype #1 in a large cohort, 3) determine the sensitivity and specificity of the new Bumps device to discriminate between healthy and neuropathic subjects; 4) continue to develop a normative database of test values and “cut off” values for diagnosis of neuropathy; and 5) Work with a marketing partner to commercialize the device. The grant period is 24 months.The Bumps: A Device for Rapid, Non-Invasive Quantification of Touch Sensation Narrative The Bumps is a deceivingly simple, hand-held, pocket-sized medical device that objectively quantifies finger pad touch sensation at the low micrometer level in 5 to 7 minutes. The purpose is early recognition, grading and monitoring progression or reversal of peripheral neuropathy secondary to diabetes, chemotherapy and other neuropathic disorders. The Bumps device is a member of a new generation of highly sensitive devices that permit earlier diagnosis and grading of neurological disorders and quantitative monitoring to evaluate the effectiveness of therapies and pharmaceuticals.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

6 SBIR/STTR records share this UEI (2011–2019). Reported award amounts total $6,504,858. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.