SBIR/STTR Research Award

Compensation-Free, Highly Multiplexed Flow Cytometer

Award identifier 3a0d414fcefbd60e8ba8830bd0079dbcc43dd9f7da2fa4785423e14e1cd62d1eAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,487,950

Program and phase

SBIR · Phase II

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
KINETIC RIVER CORP.
Proposal award date
2019-04-10
Contract end date
2021-03-31
UEI
E24FFU8H49M9
Solicitation number
PA18-574
Topic code
400

Research abstract

PROJECT SUMMARY Flow cytometry is a workhorse technique in research and development as well as in clinical laboratories for diagnosis and monitoring of disease. It is particularly useful in distinguishing between populations of immune cells based on their expressed cell surface antigens. Standard flow cytometers use fluorescent tags, often conjugated to monoclonal antibodies, to give qualitative and quantitative information about specific molecules in the cell. This molecular specificity, coupled with the fact that information is obtained on a cell-by-cell basis with very high throughput (up to 30,000 cells per second), make this a powerful technique. The ability to multiplex (measure a variety of different molecular species in a single cell) further adds to its utility and to the complexity of the scientific questions that can be addressed using this technique. However, the level of multiplexing currently has limitations. Flow cytometry analysis typically relies solely on spectral information of the fluorescent tags and is thus limited by the spectral overlap of fluorophore emissions. Currently, employing even moderate levels of multiplexing requires complex instrumentation and careful experimental design, execution and analysis to compensate for spectral spillover of signal into multiple channels. This severely limits the range of scientific questions that can be addressed using current technologies, deters novices in the technique from attempting more complex yet scientifically relevant experiments, and is widely regarded as the major bottleneck in the field. To overcome this limitation, we propose to build on our results from Phase I where we demonstrated feasibility for an innovative approach that uses fluorescence lifetime as a separate, additional discriminating measurement parameter. Our scheme for using fluorescent lifetime for multiplexing is simple, scalable, and supported by preliminary data from our prototype instrument. Here we propose to upgrade our Phase I instrument to increase multiplexing capability, challenge that instrument with a battery of verification tests, and validate using a relevant biological assay, benchmarking results against a conventional flow cytometer. The result will be a system enabling compensation-free flow cytometry experiments of 12 colors, while requiring fewer lasers and detectors than similarly equipped commercial systems. Such a system would serve a large segment of the market, including clinical cytometry, and is expected to see broad adoption. This would pave the way for further development of an ultra-high (30+) parameter instrument suitable for immunophenotyping, yet requiring significantly less compensation than current systems, and pushing the boundaries of experimental complexity. Given flow cytometry’s wide-spread use and importance, this project will have a high impact in many biomedical and clinical applications. Several large instrumentation companies have already indicated an eagerness to engage in strategic partnerships aimed at commercialization.PROJECT NARRATIVE Flow cytometry is a widely used cell-analysis technique in research and clinical diagnostics (e.g., drug development, cancer, AIDS, and other diseases). Current flow cytometers use information from fluorescent markers in a way that makes experiments complicated to perform and limits the scope of the experiments that a researcher can carry out. The current proposal aims to further develop an innovative technique that will relieve these limitations by extracting additional information from the fluorescent markers, and by using the information to simplify the operation and increase the performance of flow cytometers.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

7 SBIR/STTR records share this UEI (2017–2025). Reported award amounts total $6,068,409. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.