Research abstract
There is a critical gap in the reliability of anisotropic diffusion magnetic resonance imaging (AdMRI). This gap can be
filled by using a ground truth measurement capability that allows for the necessary parametric control of water filled
geometries of tubes at the micron scale that can produce paths representative of the millions of axons across centimeters in
brain tract trajectories. Diffusion Tensor Imaging (DTI) publications report clinically significant systematic error that
confounds accurate quantitative assessments across instruments and time. Reference phantoms that provide exact error
metrics will advance MRI biophysics science and clinical quantitative accuracy. Correction algorithms using reference data
can reduce systematic measurement error, enabling accurate reproducible measurement and provide cross scanner norms
for AdMRI pathology. This project will deliver the first viable AdMRI phantom “ground truth” using ‘Taxons™’ (textile
axon shaped nanotubes), invented by this team, and apply advanced bi-component polymer nanoscale production methods
to create structures matched to human tissue histology. In doing this we will deliver axon scale taxons at 800 nanometer
diameter, with a packing density of one million taxons per mm2, matched to actual human corpus callosum axon
measurements. In Phase I we proposed and delivered taxons with 12 micron inner diameter tubes with a packing density of
1241 per mm2 that could be filled with water and produce FA measurement in the human tissue range. We actually “over-
delivered”, exceeding a packing density of 1,000,000 per mm2 covering the human axonal tissue range. We can now
precisely parametrically control the diameters, packing density, restricted/hindered, and isotropic water fractions to test and
improve leading compartmental models of diffusion. We created a fasciculus routing machine that can, at viable cost, create
human scale fasciculus routes matched to human tissue, such as the optic system eye to LGN, of 20 million routed taxons.
The 1 to 1 scale taxonal network phantoms quantify dMRI measurement accuracy for each taxon path with 100 micron path
precision along the trajectory. We scanned the phase I phantoms at ten sites. We established in empirical studies that there
is substantial systematic, cross instrument and measurement error (e.g., 5x the TBI effect size), that the error is stable, and
can be corrected for (removed 94% of systematic error). Phase II of this project will: 1) provide the first AdMRI phantom
for ground truth measurement to quantify dMRI biophysics, spatial homogeneity, and routing precision; 2) provide fully
automated quantification of accuracy and repeatability of measurement; 3) assess AdMRI precision of 20+ sites, quantifying
measurement error at 1.5, 3, 7, 9.4 and 14T field strength; and4) develop a set of routing phantoms (Eyeandgt;LGNandgt; V1, spinal
cord and cortical tracts). These phantoms and/or subcomponents will be measured with non-MRI methods (confocal andamp;
electron microscope) using NIST traceable measurements. Researchers and center directors involved in Phase I scanning
and reviewing of the results were very positive, with 30+ sites offering free scanning time to use the phantom, and to utilize
the resulting quality assurance reports. Radiology has had phantom based pivotal successes (i.e., CT Hounsfield phantoms
in the 1990s). This project will deliver a quantitative AdMRI phantom, enabling MRI metrics to become accurate across
vendors and time implementing quantitative quality assurance (QQA).With no standard for accuracy, the field of MRI imaging has serious concerns about the accuracy of diffusion
imaging precision to produce anatomically correct maps of known anatomy. This project will advance the quality
and speed of MRI diffusion imaging to provide an anatomically accurate map of brain connectivity, providing
quantitative calibration of MRI scans for white matter pathology impacting over 10 million US residents annually
for disorders including brain trauma, tumors, developmental disorders, and neurodegenerative disorders at an
economic cost of over $80 billion. It will also provide the first viable ground truth calibration of anisotropic diffusion
to calibrate US connectome-based imaging with over $316 million dollars of research effort supported by current
NIH and Department of Defense research programs.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
Research funding history
28 SBIR/STTR records share this UEI (1993–2019). Reported award amounts total $12,487,807. Reported amounts are not federal obligations.
Phases: Phase I, Phase II
Agencies: Department of Health and Human Services, Department of Defense, National Science Foundation
Agency intelligence
Department of Health and Human Services