SBIR/STTR Research Award
Evaluating the completeness of scanning in hand-held whole breast ultrasound exams
Award amount
$205,529Program and phase
SBIR · Phase IAward year
2019Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- Metritrack, Inc.
- Proposal award date
- 2019-03-01
- Contract end date
- 2020-11-30
- UEI
- R6VYHZL6XNL5
- Solicitation number
- PA18-574
- Topic code
- NCI
Research abstract
ABSTRACT:
The project entails the development of a position-tracking system compatible with existing
hand-held ultrasound systems that can track the complete breast volume coverage with a
sufficient level of precision to avoid missing small breast cancers. Scanning the entire breast
for screening breast cancer gained increased interest in recent years, as it was shown that
supplemental screening in women with dense mammograms can significantly increase the
detection rate of small cancers. While detecting sub-centimeter lesions is essential for the
successful treatment of breast cancer, it was shown that around half of all lesions smaller
than 9 mm were not detected by experienced operators12. This significant shortcoming can
be partly attributed to an incomplete scanning of the breast caused by operatorandapos;s imprecise
visual estimation and also by large-scale deformation of the breast during the procedure. The
resultant localization error can be in the order of a few centimeters and will increase the
likelihood of missing regions of the scanned breast. Current hand-held ultrasound systems
cannot track and document completeness of scanning or alert operators of regions with
incomplete scanning. Metritrack Inc. developed a proprietary method of mapping hand-held
breast ultrasound images that was incorporated in its FDA-cleared automated breast
ultrasound system BVN G-1000. The proposed project intends to develop a method to assess
the volumetric completeness of breast ultrasound scanning, based on the proprietary
mapping method and the obtained clinical data. The project is segmented into two aims. For
aim 1, we will build a software application designed to automatically detect the breast regions
without optimal coverage and guide the operator to obtaining a complete exam. Aim 2 will
evaluate the accuracy and precision of detecting breast regions without optimal coverage.
For this purpose, a customized ultrasound breast phantom with multiple small internal targets
simulating small tumors will be built and scanned under different conditions of deformation,
by 2 operators to simulate clinical conditions of use. We expect that the outcome of this Phase
1 project will demonstrate the feasibility of building the completeness of scanning verification
and guidance application into an automated breast ultrasound system to overcome the
current limitations of breast ultrasound. The prototype will be developed into a commercially
successful product to provide standardized, complete breast ultrasound exams of the whole
breast with a higher cancer detection rate than possible today.PROJECT NARRATIVE
Detecting sub-centimeter cancers is essential for the successful diagnosis and treatment of
breast cancer; however, around half of the lesions smaller than 9 mm were reportedly
missed during ultrasonic breast scanning. A significant number of these missed lesions can
be attributed to incomplete scanning of the breast due to the operatorandapos;s imprecise visual
estimation and large-scale deformation of the breast during the procedure. It is our goal to
develop a position-tracking system compatible with existing hand-held ultrasound systems
that can track the completeness of breast volume coverage with a sufficient level of
precision to avoid missing small breast cancers.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- Mini-reflectance confocal microscope (Mini-RCM) for aiding skin cancer diagnosis and treatment
- Development of small molecule therapeutics targeting AR-V7 for prostate cancer
- Decentralized Clinical Trial of Effectiveness of EnergyPoints App to Guide Acupressure Use for Fatigue and Sleep Disturbances in Cancer Survivors
- Optimized targeted radiotherapy of pancreatic cancer
- Adaptive imaging for pioneering multiplexed spatial profiling of tumors and tissues for cancer research and diagnosis