SAM.gov listing

URC-300 VHF/UHF Transceiver Assembly and Remote Control Unit (RCU)

Department of Defense → Department of the Air Force → AIR Force Materiel Command → AIR Force TEST CENTER → FA9302 AFTC PZZCombined Synopsis/SolicitationSolicitation ACQ-26-H096

Response deadline

Sun, Sep 3, 2028, 4:00 PM EDT
Analyze This Opportunity in CaptureIQ

Compare your company's capabilities against this federal opportunity using CaptureIQ.

Ready to Pursue This Opportunity?

Qualify the fit, analyze competitors, identify teaming partners, and generate review-ready materials — all in CaptureIQ.

  • Federal capture workflow
  • Competitor & teaming intelligence
  • Proposal preparation

Opportunity details

NAICS
334220
Notice type
Combined Synopsis/Solicitation
Original posted
August 31, 2026
Last updated
October 18, 2026
Notice ID
5da0445b59c84423bcdaec7ba5b3a612

Summary

The Department of the Air Force, Air Force Materiel Command (AFMC), Air Force Test Center (AFTC), AFTC/PZZF, Edwards AFB, CA, hereby issues this Combined Synopsis/Solicitation and Notice of Intent to award a sole-source, Firm-Fixed-Price (FFP) purchase order. This transaction is conducted pursuant to RFO 6.103-1, "Only one responsible source and no other supplies or services will satisfy agency requirements," as implemented by RFO FC 12.201-1, "Simplified procedures." The Government intends to award a sole-source contract exclusively to ACG Systems, Inc. (CAGE: 1FRK9; COTS Vendor/Small Business), located at 133 Defense Highway, Annapolis, MD 21401-7023. 2. REQUIREMENT DESCRIPTION: The Contracting Officer has determined that only the following original equipment manufacturer (OEM) part numbers can satisfy the agency’s critical technical requirements: - Line Item 01: [P/N: 01-P58564R002] URC-300 VHF/UHF Transceiver Assembly, COTS, O&M Manual (Qty: 1 EA) - Line Item 02: [P/N: US00240100-001] Universal Mounting Bracket System for URC-300 (Qty: 1 EA) - Line Item 03: [P/N: 30-P58549R001] DC Power Cable (Qty: 1 EA) - Line Item 04: [P/N: 85-P39217N001-C3] VHF/UHF Spring Loaded Mobile Antenna (Qty: 1 EA) - Line Item 05: [P/N: US00300049-001] Antenna Mounting Bracket, Roof Mount with Integrated Cable (Qty: 1 EA) - Line Item 06: [P/N: 50-P53272R001-C3] Speaker Microphone (Qty: 1 EA) - Line Item 07: [P/N: 01-P57870R001] Remote Control Unit (RCU) enabling CM-350 V2 dual transceiver control (Qty: 1 EA) - Line Item 08: [P/N: 60837-001] Palm Microphone for CM-300/350 (V2) Transmitter (Qty: 1 EA) - Line Item 09: [P/N: SH-40] Receiver/Transmitter Compatibility Connector (Qty: 1 EA) - Line Item 10: [P/N: 30-P58653R050] URC-300 to RCU Audio Interface Cable, 50 ft (Qty: 1 EA) - Line Item 11: [P/N: 15-P58596R002] URC-300 Battery Connector Cover (Qty: 1 EA) 3. DETERMINATION AND JUSTIFICATION: ACG Systems, Inc. is the Original Equipment Manufacturer (OEM) and maintains a strict direct-sales model with zero authorized third-party distributors or resellers for Air Force acquisitions. The required hardware represents an expansion of the existing URC-300 baseline telemetry suite integrated under previous contract FA9302-22-F-G596. This equipment is technically required to natively interface with the B-52 CERP Mobile Telemetry Van's proprietary CM-350 V2 control protocols and must satisfy mandatory military TEMPEST/EMI shielding requirements. Procurement of alternative commercial hardware is legally and economically restricted. Sourcing non-ACG hardware would render the existing subsystem entirely inoperable, resulting in a direct, severe duplication of hardware and integration labor costs. Furthermore, introducing an uncertified brand would trigger a mandatory, comprehensive TEMPEST recertification of the Mobile Telemetry Van and introduce a critical 6-to-9-month laboratory testing delay. This delay would halt telemetry flight-test support, directly threatening overall B-52 engine replacement timelines and Chief of Staff of the Air Force (CSAF) operational readiness targets. In accordance with RFO policies, this requirement cannot be satisfied through any mandatory source, including AbilityOne or UNICOR. 4. RESPONSE INSTRUCTIONS AND POINT OF CONTACT: This notice of intent does not constitute a competitive Request for Quotes (RFQ) or Request for Proposals (RFP). However, in accordance with RFO FC 12.202, any responsible source that believes it can satisfy the aforementioned requirements may submit a formal capability statement. To be considered, any prospective challenger must submit written, legally binding documentation demonstrating: A) Direct, unmodified technical compatibility with the proprietary CM-350 V2 Remote Control Unit protocols. B) Current military TEMPEST and EMI certification data for integration into 419FLTS classified shelters. C) Explicit, written authorization from the OEM (ACG Systems, Inc.) verifying reseller or distributor status. All capability statements must be submitted via email to Contract Specialist/Contracting Officer Josiah Broadway at josiah.broadway@us.af.mil no later than September 3, 2026, at 12:00 PM Pacific Standard Time (PST). A determination by the Government not to compete this proposed action based upon responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement in the future.

Read Full Official Summary

The Department of the Air Force, Air Force Materiel Command (AFMC), Air Force Test Center (AFTC), AFTC/PZZF, Edwards AFB, CA, hereby issues this Combined Synopsis/Solicitation and Notice of Intent to award a sole-source, Firm-Fixed-Price (FFP) purchase order. This transaction is conducted pursuant to RFO 6.103-1, "Only one responsible source and no other supplies or services will satisfy agency requirements," as implemented by RFO FC 12.201-1, "Simplified procedures." The Government intends to award a sole-source contract exclusively to ACG Systems, Inc. (CAGE: 1FRK9; COTS Vendor/Small Business), located at 133 Defense Highway, Annapolis, MD 21401-7023. 2. REQUIREMENT DESCRIPTION: The Contracting Officer has determined that only the following original equipment manufacturer (OEM) part numbers can satisfy the agency’s critical technical requirements: - Line Item 01: [P/N: 01-P58564R002] URC-300 VHF/UHF Transceiver Assembly, COTS, O&M Manual (Qty: 1 EA) - Line Item 02: [P/N: US00240100-001] Universal Mounting Bracket System for URC-300 (Qty: 1 EA) - Line Item 03: [P/N: 30-P58549R001] DC Power Cable (Qty: 1 EA) - Line Item 04: [P/N: 85-P39217N001-C3] VHF/UHF Spring Loaded Mobile Antenna (Qty: 1 EA) - Line Item 05: [P/N: US00300049-001] Antenna Mounting Bracket, Roof Mount with Integrated Cable (Qty: 1 EA) - Line Item 06: [P/N: 50-P53272R001-C3] Speaker Microphone (Qty: 1 EA) - Line Item 07: [P/N: 01-P57870R001] Remote Control Unit (RCU) enabling CM-350 V2 dual transceiver control (Qty: 1 EA) - Line Item 08: [P/N: 60837-001] Palm Microphone for CM-300/350 (V2) Transmitter (Qty: 1 EA) - Line Item 09: [P/N: SH-40] Receiver/Transmitter Compatibility Connector (Qty: 1 EA) - Line Item 10: [P/N: 30-P58653R050] URC-300 to RCU Audio Interface Cable, 50 ft (Qty: 1 EA) - Line Item 11: [P/N: 15-P58596R002] URC-300 Battery Connector Cover (Qty: 1 EA) 3. DETERMINATION AND JUSTIFICATION: ACG Systems, Inc. is the Original Equipment Manufacturer (OEM) and maintains a strict direct-sales model with zero authorized third-party distributors or resellers for Air Force acquisitions. The required hardware represents an expansion of the existing URC-300 baseline telemetry suite integrated under previous contract FA9302-22-F-G596. This equipment is technically required to natively interface with the B-52 CERP Mobile Telemetry Van's proprietary CM-350 V2 control protocols and must satisfy mandatory military TEMPEST/EMI shielding requirements. Procurement of alternative commercial hardware is legally and economically restricted. Sourcing non-ACG hardware would render the existing subsystem entirely inoperable, resulting in a direct, severe duplication of hardware and integration labor costs. Furthermore, introducing an uncertified brand would trigger a mandatory, comprehensive TEMPEST recertification of the Mobile Telemetry Van and introduce a critical 6-to-9-month laboratory testing delay. This delay would halt telemetry flight-test support, directly threatening overall B-52 engine replacement timelines and Chief of Staff of the Air Force (CSAF) operational readiness targets. In accordance with RFO policies, this requirement cannot be satisfied through any mandatory source, including AbilityOne or UNICOR. 4. RESPONSE INSTRUCTIONS AND POINT OF CONTACT: This notice of intent does not constitute a competitive Request for Quotes (RFQ) or Request for Proposals (RFP). However, in accordance with RFO FC 12.202, any responsible source that believes it can satisfy the aforementioned requirements may submit a formal capability statement. To be considered, any prospective challenger must submit written, legally binding documentation demonstrating: A) Direct, unmodified technical compatibility with the proprietary CM-350 V2 Remote Control Unit protocols. B) Current military TEMPEST and EMI certification data for integration into 419FLTS classified shelters. C) Explicit, written authorization from the OEM (ACG Systems, Inc.) verifying reseller or distributor status. All capability statements must be submitted via email to Contract Specialist/Contracting Officer Josiah Broadway at josiah.broadway@us.af.mil no later than September 3, 2026, at 12:00 PM Pacific Standard Time (PST). A determination by the Government not to compete this proposed action based upon responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement in the future.

Official SAM.gov Contract Opportunities file extract description for this notice. CaptureIQ does not generate or rewrite this text.

Related Federal Opportunities

Why this matters

  • This notice is a combined synopsis/solicitation.
  • The listed response deadline is Sep 3, 2028.
  • 4 related opportunities share this NAICS.

Related federal terms

  • NAICS — North American Industry Classification System
  • PSC — Product Service Code

Market context

4 Related OpportunitiesMatching opportunities on RFPCapture

Related intelligence

Research and capture tools

Initial findings on CaptureIQ pursue / no-pursue patterns — cite only with disclosed sample limits.

← All federal opportunities · Federal Opportunity Research

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.