SBIR/STTR Research Award

Bactericidal Intravascular Biosensor for Continuous Reading of Lactate in the lCU Ph2

Award identifier ab2f7a30d55b9b114e7016d63d83307bdf91eaf8ad7acfde77e6ad961bc0f353Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,377,585

Program and phase

SBIR · Phase II

Award year

2018

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
BIOCREDE INC.
Proposal award date
2018-05-01
Contract end date
2020-04-30
UEI
K718SE8C5CY5
Solicitation number
PA17-302
Topic code
300

Research abstract

PROJECT SUMMARYABSTRACT In Phase IBiocrede developed a wirelessFrflexibleand aFrdual lumencatheternitric oxideNOreleasingin vivo tested without heparin injectionscontinuous lactate sensor that can wirelessly monitor intravenousIVblood lactate levels to alert caregivers in the ICU when lactate levels riseElevated blood lactate levels are associated with major morbidity and mortality in critically ill patients recovering from organ transplantation or traumaand in pediatric patients with congenital heart diseaseCHDundergoing cardiac surgery with cardiopulmonary bypassCPBOur sensorsBiocrede IPprovisional patents USand USpossess NO releasing technologyLicensed from the University of Michiganthat prevents thrombosis fordays that otherwise renders IV sensors inoperable inaccurate within minutes in nonheparinized or inadequately heparinized patientsThis novel device can be used to discriminate between infants at high and low risk of morbidity and mortality after CHD surgeryand allow care providers to intervene earlier to prevent adverse outcomesKey features of the non tethered sensor includeproven thrombosis protection tested forhours in pigsNO releases fordaysfold reduction of live bacteria counts on surface with NO for andgtdayssafest scores on ISO GLP leachingimplantationand cell toxicity testscontinuous lactate readout ability fordays everysecondsandability to discern increasing lactate levels withinmin without requiring a blood sample compared to current blood gas instrumentsThe pediatric interventional cardiology market is estimated at $MM bywith a CAGR ofthe blood and electrolyte testing market was $B inwith a CAGR of$MM byand the global sepsis therapeutics market is estimated to be $B bywith a CAGR ofIn Phase II we propose toManufactureperform quality controland setup the design history files and device master records for the full development and manufacture of devices following ISOFDA requirementimplant lactate sensing dual lumen central venous cathetersCVCin femoral vein for continuous measurement of endogenous lactic acid production in rabbit model of cardiopulmonary bypass and cardioplegic arrestnto determine best lactate increase rate detection timesandfinalize GLP biocompatibility studiesestablish IRB and file first submission to FDA to perform an acute clinical study of lactate sensors in infants with CHD undergoing CPB at the University of Michigan C SMott Childrenandapos s Hospital Congenital Heart CenterJCharpieCo DirectorBiocredeUS ownedmanufactures the sensors and assembles these into OEM ed FDA approved CVCs NARRATIVE Blood lactate levels and lactate rate of change are valuable parameters to measure during resuscitation of critically ill patients with organ failure and sepsisand in infants with congenital heart disease undergoing heart surgery with cardiopulmonary bypassRising blood lactate levels are indicative of tissue hypoperfusion or poor oxygenationand a shift from aerobic to anaerobic cellular respirationThese pathophysiologic changes often precede circulatory failureand correlate with major morbidity and mortality in the intensive care unitA point of care device that can continuously quantitate blood lactate levels in real time will better predict impending circulatory failure than current benchtop blood analyzers that may providehour discrete measurements

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

6 SBIR/STTR records share this UEI (2013–2018). Reported award amounts total $3,547,593. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.