SBIR/STTR Research Award

Novel Continuous Esophageal Pressure Monitoring Catheter with Feeding Tube

Award identifier 298747b54c678d603e3a599a199dcd3120287bbad8b1394d5c6640890b793216Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$224,923

Program and phase

SBIR · Phase I

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
RUSH RIVER RESEARCH CORP
Proposal award date
2017-09-12
Contract end date
2019-08-31
UEI
LU32GMNHHNW1
Solicitation number
PA16-302
Topic code
NICHD

Research abstract

PROJECT SUMMARY ABSTRACT Over US adults and children are on mechanical ventilators in intensive care units each year While major advancements in ventilator devices have improved outcomes for critically ill patients current ventilator practice is predominately based on measurements of airway pressure The more relevant pressure particularly to determine if mechanical ventilation is causing harm is the pressure across the alveoli or transpulmonary pressure During controlled ventilation accurate measurements of transpulmonary pressure can help adjust ventilator settings to minimize ventilator induced lung injury which leads to multiple organ failure inability to wean from mechanical ventilation and death Accurate transpulmonary pressure measurements require an estimate of pleural pressure which is not feasible to measure directly in humans Esophageal pressure is an accepted surrogate for pleural pressure with esophageal balloon catheters serving as the most commonly used method for measurement Recent research in both adults and children highlight many potential benefits of measuring esophageal pressure but these measurements are often limited to research centers that have developed expertise in using esophageal balloon catheters Balloon catheters have many limitations related to placement dependence on balloon filing volume cardiac artifact and patient size and position Hypothesis We hypothesize an easier to use more accurate and more stable pressure sensing catheter can be made using a fiber optic pressure sensor integrated with a feeding tube Providing an easy to use stable and accurate pressure sensing catheter that can remain in the patient for weeks at a time and be used for feeding will increase the number of patients who will benefit from esophageal pressure measurements Specific Aims Rush River Research RRR Corporation proposes to develop a novel catheter to provide simultaneous esophageal pressure esophageal temperature and feeding for use in ventilated patients In aim we will develop prototype catheters with integrated pressure sensor temperature sensor and feeding tube which meet FDA standards for mechanical efficiency In aim we will evaluate the catheter s accuracy in simulated pleural pressure measurement and determine the frequency with which ex vivo calibration is needed using a laboratory model Aim will test the catheter s responsiveness to real changes in pleural pressure and determine if it is robust against common sources of artifact using an animal model Team RRR has assembled a highly qualified team of critical care researchers and a major OEM catheter developer and manufacturer to achieve these goals PROJECT NARRATIVE There is growing research showing the importance of measuring esophageal pressure as a surrogate for pleural pressure for patients on mechanical ventilators The most common measurement method uses a balloon catheter whose accuracy can vary based on patient anatomy balloon position balloon inflation and the presence of other tubes in the esophagus A new combination catheter is needed to provide more accurate esophageal pressure measurements which is easy to use and has an incorporated feeding tube and temperature sensor

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

12 SBIR/STTR records share this UEI (2016–2025). Reported award amounts total $5,198,181. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.