SBIR/STTR Research Award
Removable transcatheter aortic valve
Award amount
$212,884Program and phase
SBIR · Phase IAward year
2017Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- ReValve Med, Inc.
- Proposal award date
- 2017-08-01
- Contract end date
- 2018-01-31
- UEI
- Not reported
- Solicitation number
- PA16-302
- Topic code
- NHLBI
Research abstract
Our long term goal is to develop and commercialize a replaceable transcatheter aortic valve TAV which is
initially deployed with a covered base anchored within native diseased aortic valve without paravalvular
leakage and a separate modular valve component inside the base Years later after transcatheter aortic valve
replacement TAVR degenerates and fails the modular valve component can be retrieved and replaced with
another valve component via transcatheter approach with a temporary valve Goal of Phase I SBIR is to
develop two component TAV with base and replaceable valve and demonstrate retrievability of valve after
implantation and release within the base To date no TAV on the market or in development has demonstrated
this key step of retrieval after TAVR deployment Success of Phase I would lead to Phase II where we would
demonstrate modular valve component replacement using a temporary valve for hemodynamic stability during
deployment TAVR revolutionized treatment of severe aortic stenosis AS Randomized clinical trials proved
TAVR improved survival over medical therapy for inoperable patients making TAVR the gold standard therapy
Transfemoral TAVR also showed equivalent or superior outcomes when compared to surgical aortic valve
replacement for high risk and now intermediate risk patients Large randomized trials are currently underway
for low risk surgical patients with small studies showing TAVR and SAVR equivalence As TAVR expands to
younger less risky patients durability becomes TAVRandapos s Achilles heel Alarmingly new TAVR durability data
presented at EuroPCR May showed early TAVR degeneration within years with degeneration
at years As TAVR expands to surgical patients s years old a clinical unmet need has emerged to
develop TAVR devices with replaceability as an option We hypothesize that expanding TAVR to younger low
risk surgical patients will require a replaceable TAV to overcome limited TAVR durability Our innovative
solution is to develop a replaceable TAVR using a component modular system a permanent hollow covered
base with a removable valve component that can be replaced Current rd generation TAVR have the ability to
retrieve and reposition the valve for precise positioning during the implantation but once released none of the
current designs allow for removability and replacement Our goal here is to demonstrate removability of TAVR
valve component once fully released We propose following aims Test a two component TAVR prototype
with fully retrievable removable valve component and implant in vitro in pulse duplicator to assess
hemodynamics Demonstrate TAVR valve component repositionability then full release from delivery system
Demonstrate TAVR valve component retrievability and removability by the retrieval system after full release
of the TAVR Phase I SBIR is the first step towards offering younger healthier patients a removable and
replaceable TAV Our Phase II goals will be developing delivery systems with embedded temporary valve for
hemodynamic stability and filters to capture embolic debris during TAVR valve removal and reimplantation Over patients worldwide undergo surgical aortic valve replacement each year However
transcatheter aortic valve replacement TAVR has become the gold standard for inoperable
patients and has shown equivalence if not improved survival compared to surgery in
intermediate and high risk patients Now TAVR is moving to the surgical patient population but
its durability is far inferior estimated to be years compared to years with surgical
bioprostheses The goal of this project is to develop a two component transcatheter aortic valve
consisting of a base and modular valve component so that young surgical patients can have a
transcatheter approach which allows these valves to be removed and replaced without surgery
when these valves fail
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- DUCTUS ARTERIOSUS STENT TO IMPROVE CONGENITAL HEART DEFECT MORTALITY
- Head Up CPR and Aortic Occlusion to Improve Survival after Refractory Cardiac Arrest
- Free-Breathing Dynamic Cardiopulmonary Function Imaging System to use with Xenon MRI
- The Next Wave of Asthma Therapeutics
- Bearingless flux reversal motor for neonatal and pediatric extracorporeal life support applications