SBIR/STTR Research Award

Insert Earphones with Integrated In Ear Calibration

Award identifier 1a3798ce2f62ec0edb48d98c360da9c19b79f536f4c4a7425fa19c40ef9d2f67Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$148,419

Program and phase

SBIR · Phase I

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
INTELLIGENT HEARING SYSTEMS CORP
Proposal award date
2017-06-20
Contract end date
2019-05-31
UEI
P6QDBDAB9KS4
Solicitation number
PA16-302
Topic code
Y

Research abstract

The specific aim of this project is to develop an insert earphone with integrated in ear sound level calibration capabilities Insert earphones provide great advantages for hearing testing with a convenient and comfortable way to deliver a stimulus with high noise and intra aural attenuation They not surprisingly have become a standard clinical transducer However their exact calibration over a wide range of ages from neonates to older adults is questionable due to differences in ear canal volumes ranging from to cc The current use of the same calibration values on such a wide range of populations significantly limits the effectiveness of calibration resulting in a wide range of sensation levels for a given calibrated stimulus A simple and easy way to provide routine in ear calibration of signals being delivered using insert earphones is necessary in order to standardize clinical testing across populations and clinics In order to develop the proposed system the following work will be conducted during Phase I Develop insert earphone that incorporates a miniature microphone preamplifier and equalizer circuitry in the transducer assembly Develop a full range of insert earphone disposable tips with a built in microphone probe tube that can be used for pediatric and adult testing Develop a stand alone dual channel microphone amplifier with a Digital Signal Processor DSP based hardware and software component usable with any audiometric test system providing on screen calibration values during testing Perform a comprehensive bench mark and validation testing of the system on a wide range of test cavities and stimulus frequencies The newly developed inserts will be fully compatible with our recently developed USB Jr Duet hardware platform which provides dual built in microphone amplifiers allowing immediate integration of the proposed system to current IHS users A proposed stand alone dual microphone amplifier component will allow integration with rd party audiometric testing devices that use insert earphones but that do not have the built in microphone amplifier capabilities The stand alone module will provide on screen calibration measurements concurrently to any other testing application running on the user s computer The proposed system will provide an easy to use and integrated approach to in ear calibration for insert earphones The device will result in a direct benefit to patients by providing in vivo calibration information that will in turn provide more accurate diagnostic and normative information and result in better patient management with better outcomes During Phase II a comprehensive clinical trial is envisioned on a wide range of subjects ranging from neonates to adults comparing Auditory Evoked Potential AEP recordings Middle Ear Muscle Reflexes MEMR and audiometry threshold results using standard and the proposed in ear calibration techniques The development of insert earphones with integrated in ear calibration capabilities will provide a great clinical advantage in hearing evaluation with these types of transducers Current insert earphones are calibrated using adult ear canal models which do not resemble the broad range of volumes in their target testing population from newborns to adults As such a there is currently a wide range of variability in the sensation level of the stimulus being delivered with these devices The proposed device will provide an easy to use method for measuring the output level in the ear of every patient and adjusting the stimulus accordingly As such the proposed work will greatly impact public health by providing comparable stimulation levels across all patients regardless of ear canal volume which will provide better diagnostic and treatment information

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

38 SBIR/STTR records share this UEI (1991–2025). Reported award amounts total $12,140,171. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services, Department of Education

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.