SBIR/STTR Research Award

INEXPENSIVE BRAZELESS MEDICAL ACCELERATOR

Award identifier 67b15a9252c976fed33ff84caa4b95d2be9f4ce086508e62065cba05ae3fcd81Awarding agency Department of Energy

Award amount

$149,013

Program and phase

SBIR · Phase I

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
EUCLID TECHLABS, LLC
Proposal award date
2017-06-12
Contract end date
2018-03-11
UEI
J7DNBL8YF4A2
Solicitation number
DE-FOA-0001619
Topic code
24a

Research abstract

The cost of the accelerating waveguide in modern medical accelerators and industrial linacs is substantial. This comes to no surprise as the accelerating waveguide is a set of diamond – turned copper resonators brazed together. Such a multistep manufacturing process not only expensive, but also prone to manufacturing errors, which decrease the production yield. In the big picture, the cost of accelerating waveguide prohibits the use of accelerators as a replacement option for radioactive isotopes. This is especially true for systems intended for operation in an environment with electricity, temperature, humidity and water supply issues. Ultimately, an inexpensive and robust accelerator is needed. Euclid Techlabs LLC proposes a revolutionary brazeless accelerating structure made out of copper- plated stainless steel or tungsten cells with copper irises serving as gaskets for vacuum and RF seals. Skipping the brazing step and using stainless steel components reduces cost compared to copper. Because of a smaller half-value layer for stainless steel or tungsten, the shielding weight is also reduced. Brazeless design allows the addition of cooling channels and embedded focusing magnets for performance optimization. Embedded focusing/steering elements allow for a small bore, lower current focusing coil for a significant weight and space reduction. In Phase I we will design and fabricate a proof-of-principle prototype of an accelerating waveguide operating at an energy of 1 MeV. This will be a full accelerating structure with integrated microwave coupler which also will be brazeless. This prototype will be cold tested and prepared for a beam test. Besides the industrial application, this robust and inexpensive accelerator will find application as an isotope replacement. Due to increased regulations imposed by US Nuclear Regulatory Commission (NRC) there are additional indirect expenses associated with radionuclide based sources. These expenses are associated with the disposal of the radionuclide source of the irradiator. The proposed inexpensive design makes radiation-on-demand accelerator – based gamma ray sources commercially viable.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

99 SBIR/STTR records share this UEI (2002–2025). Reported award amounts total $41,359,807. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Energy

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.