SBIR/STTR Research Award
C i Supplement Development of an Active Spinal Orthosis for the Treatment of Vertebral Compression and Burst Fractures
Award amount
$258,528Program and phase
SBIR · Phase IAward year
2016Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- EXO DYNAMICS LLC
- Proposal award date
- 2016-09-30
- Contract end date
- 2018-03-30
- UEI
- Not reported
- Solicitation number
- PA17-286
- Topic code
- NIBIB
Research abstract
Significance of Research Exo Dynamics seeks to develop a novel active spinal orthosis that will enhance the
outcomes of bracing treatment for the most common osteoporotic spinal fractures The goal is to create a
device that will enhance outcomes through monitored use and provide consistent continuous support through
a complete range of motion ROM This device may reduce pain enhance mobility lead to a higher quality of
life and reduce the rate of subsequent fractures for patients exiting bracing treatment
Description of the Problem Patients may exit current bracing treatment with suboptimal mobility and reduced
strength in their lower backs due to orthosis imposed immobilization Currently patients are instructed to
undergo a weaning process near the end of treatment to counter these effects but a reliance on patient
discipline and crude methods often yields mixed results
Description of Technology and Long Term Goal Unlike existing passive braces the proposed brace or
orthosis will incorporate a closed loop electromechanical control and actuation system to monitor whether a
patient is using the brace and provide time dependent adjustment of ROM and perceived stiffness allowing
automated bracing and weaning for spinal Compression Burst Fracture CBF patients The goal is to bring to
market this novel medical device with the potential to automate and customize bracing treatment for this large
and growing patient population as well as improving ROM strength pain levels and subsequent fractures
Phase I Hypothesis and Specific Aims An active back brace a thoracolumbosacral spinal orthosis TLSO can
be constructed that is capable of supporting times the mass of the upper body of a person throughout a
specified ROM and can be worn for two weeks during a simulated bracing and weaning protocol with no
visible signs of skin breakdown The proposed work is organized into three specific aims the first tests the
load bearing and maneuverability of the mechanical portions of the device the second tests the active response
support behavior of the electronic control system and the third is a trial with a small pool of healthy human
subjects wearing the device throughout a compressed simulated treatment protocol lasting two weeks
Plans for Phase II The design of the prototype orthosis will be finalized incorporating Phase I results A
randomized control study of up to patients in groups control standard bracing followed by prototype
weaning prototype bracing and weaning will then be conducted to study the efficacy of the proposed orthosis
Commercial Application Up to CBFs occur annually in the United States resulting in up to $ billion
in treatment costs Nearly of all CBF patients will experience one or more additional fractures within one
year of treatment The spinal orthosis market is projected to be $ million of which $ million is for
custom fabricated devices in Exo Dynamics will assemble and distribute the devices through orthotics andamp
prosthetics centers with acquisition by an established leader as a potential exit Project Narrative
In this Phase I SBIR Exo Dynamics LLC plans to develop a novel active spinal orthosis for
enhancing the outcomes of bracing treatment for osteoporotic vertebral compression and burst
fractures Their goal is to create a device which can enhance compliance and mobility and lower
the risk of subsequent fractures leading to a higher quality of life for patients exiting their
orthotic treatment
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- Deep-UV Microscopy for Real-Time Adequacy Analysis of Bone Marrow Aspirates
- Deep learning image classification model for pediatric ear disease
- Development of a Multispectral Kerrison Rongeur for Dura and Nerve Root Detection
- Non Invasive Urine Output Monitor
- SoundScape: A portable small animal imager to accelerate drug development