SBIR/STTR Research Award

High Energy Density Polymer Film Capacitors for ICDs

Award identifier 57c131e9f5d7e2d308f7a43252480926735210b402adfdcf34bc96318640fac9Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$150,000

Program and phase

SBIR · Phase I

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
HARP ENGINEERING LLC
Proposal award date
2016-08-01
Contract end date
2018-08-31
UEI
XCAZPC3M2TP7
Solicitation number
PA15-269
Topic code
NHLBI

Research abstract

Project Summary An implantable cardioverter defibrillator ICD is a small battery powered electric pulse generator about the size of a stopwatch that is implanted into the chest of patients who are at risk of sudden cardiac death due to ventricular fibrillation and ventricular tachycardia The ICD uses a capacitor to deliver a shock defibrillation to the heart which stops the abnormal rhythm Without this therapy the dangerously rapid rhythm could lead to sudden cardiac arrest and sudden cardiac death within minutes Sudden death due to cardiac arrest affects people each year in the United States alone meaning that almost people die from it each day ICDs have been shown to effectively stop or more of these dangerously fast heart rhythms ICDs place unique requirements on the capacitor used to generate the electrical pulse requiring a combination of high voltage high capacitance and small case size While metalized polymer film capacitors are used AEDs the energy density of current materials is too low to be used in implantable devices Without the availability of high energy density polymer films ICDs have been limited to aluminum electrolytic capacitors which are undesirable for many reasons resulting from the use of a liquid electrolyte Polymer film capacitors are solid state and thus require no volatile compounds that would pose safety risks once implanted Existing polymer film capacitors such as those produced from polypropylene or polyethylene have a low volumetric capacitance and low energy density J cc making them unsuitable for ICDs HARP Engineering recently developed a new composition for thin film capacitors that provides the highest energy density ever reported This technology is would allow a times smaller capacitor than the aluminum electrolytic capacitors used in current implantable cardioverter defibrillators ICDs and a reduction in total device volume Since ICDs are implanted the package size is critical to the patientandapos s quality of life after surgery especially in pediatric cases and the reduction of late complications such as skin erosion which is highly impacted by the size of the device and reported to occur in of cases Furthermore the more recent development of subcutaneous ICDs which eliminate complications from intravenous leads require roughly three times greater energy to achieve defibrillation thus producing even greater need for smaller capacitors Under this SBIR HARP Engineering proposes to collaborate with St Jude Medical and Boston Scientific to manufacture test and demonstrate ultra high energy density capacitors for use in ICDs Project Narrative Implantable cardioverter defibrillators ICDs are implanted into the chest of patients who are at risk of sudden cardiac death due to ventricular fibrillation and ventricular tachycardia The proposed SBIR seeks to develop a polymer film capacitor that can reduce the total ICD volume by leading to greater patient comfort improved reliability and reduced late complications

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

14 SBIR/STTR records share this UEI (2010–2020). Reported award amounts total $4,543,013. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, National Aeronautics and Space Administration, Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.