SBIR/STTR Research Award

Advanced Polymer-Based Micro-sensor for Radiation Detection and Measurement

Award identifier 67b3b25ffb9740abcf7723f2cba11c7767f61d6d6373b856e80f4a2750c71f14Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$221,432

Program and phase

STTR · Phase I

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
SEACOAST SCIENCE, INC.
Proposal award date
2016-08-01
Contract end date
2018-01-31
UEI
CM2UZ96ZVKS8
Solicitation number
PA15-270
Topic code
NIEHS

Research abstract

Project Summary This Small Business Technology Transfer Phase I project proposes the development and optimization of a commercially viable novel polymer based radiation dosimeter for wide spread deployment The radiation dosimeter proposed herein is a disruptive technology with a significant market Although many commercial radiation dosimeters measure individual radiation load dose quantification and exposure timing the value proposition of the device described herein is the equivalent performance with a fold reduction in price Upon optimization commercialization and production the dosimeter will allow the real time individual radiation exposure Initial products will target niche markets with higher radiation exposure probability such as nuclear power plant personnel Further optimization in sensitivity will open broader markets such medical applications i e x ray technician and in radiation oncology Finally in service to the overall goal of NIEHS to provide sensors for environmental monitoring the cost and performance of the proposed dosimeter will allow widespread personnel deployment to determine the individual radiation load for a large population Hence Seacoast Science Inc and Professor Timothy Swager MIT jointly propose this dosimeter based on underlying principles technology developed at MIT Angewandte Chemie In that initial work a two electrode conductive dosimeter was coated with a multi walled carbon nanotube MWCNT polymer blend upon exposure to gamma radiation the measured conductance increased from increased interconnected nanocircuitry Despite impressive results the conductive measurement required sensitive research grade electronics Furthermore the initial polymer MWCNT polymer blends displayed sub optimum sensitivity Technical hurdles are addressed in this project optimizing the polymer MWCNT sensitivity use of a more sensitive dosimeter platform and design fabrication of an appropriate badge size readout Accordingly during this Phase I project a series of polyolefin sulfones with side groups selected for optimal polymer MWCNT interaction and maximum radiation gamma cross sectional area will be synthesized at MIT These polymers will be combined with different grades of multi walled carbon nanotubes to produce novel blends The blends will be coated onto Seacoast Science s proprietary capacitive sensor platform and appropriate accompanying electronics will be designed and fabricated The analytical performance of these novel dosimeters will then be determined using the radiation source at MIT The underlying hypothesis is that the sensor microstructure and the capacitive transducer will result in enhanced sensitivity when combined with the Swager polymer CNT materials in these radiation dosimeters Because the radiation induced depolymerization gives rise to increased CNT CNT contacts the distance over which charge can be polarized also dramatically increases These space charge effects are the largest contributor to a capacitance and will be easily measured at much lower radiation exposures than exposures required to form a percolating conductive network between electrodes The analytical performance of the dosimeters will be determined by exposure to increasing doses of gamma radiation the response measured and the optimal polymer blends selected for further Phase II development Project Narrative This Phase I Small Business Technology Transfer project proposes the development and optimization of a low cost commercially viable novel radiation dosimeter The badge sized device will allow population based studies of radiation exposure The device will also improve worker health in high risk industries by allowing a real time exposure detection and time integrated dosimetry and by noting the time and extent of exposure rather than the total radiation load averaged over a certain time period

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

67 SBIR/STTR records share this UEI (2004–2025). Reported award amounts total $21,050,156. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Defense, Department of Health and Human Services, Environmental Protection Agency, Department of Agriculture, National Aeronautics and Space Administration, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.