SBIR/STTR Research Award

Highly Accelerated Simultaneous Multi Slice Phase Contrast MRI

Award identifier 4ea8090c5bf420152cfe1ba0c53b2619e514e935e5d4a5fa7603b72ac28b3410Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,656,876

Program and phase

SBIR · Phase II – Direct to Phase II

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ADVANCED MRI TECHNOLOGIES LLC
Proposal award date
2016-08-01
Contract end date
2019-07-31
UEI
JJ45PN66LSE7
Solicitation number
PAR14-088
Topic code
101

Research abstract

DESCRIPTION provided by applicant MRI phase contrast velocity imaging is a widely disseminated on nearly all MRI scanners used for clinical diagnosis of brain disease cardiac and cardiovascular disease and for neuroscience research Currently phase contrast imaging of blood flow and CSF motion requires longer scan times with each D slice or D spatial image requiring additional dimension of velocity encoding requiring greater acquisition time Given the physiological variation in heart rate cardiac stroke output and respiratory motion effects on blood and CSF velocity no less the need to greatly reduce the patients time in the scanner there is a need to reduce the scan time of phase contrast imaging To achieve several times faster imaging we propose to develop novel technology to acquire velocity phase images simultaneously instead of seperately Our new technique called simultaneous multi slice imaging SMS phase contrast PC imaging is innovated to obtain phase contrast images recorded simultaneously resulting in nearly this factor of reciprocal reduction in scan time The availability of the new simultaneous phase contrast imaging technology will give clinicians and researchers the capability of performing significantly improved MRI perfusion measurements in the and these improvements will impact the diagnosis of many different diseases including stroke cardiac cardiovascular diseases Additionally blood flow and CSF flows which are important quantitative biomarkers useful as physiological imaging in evaluating new drug therapies for diseases This family of new phase contrast imaging techniques utilizes more efficient pulse sequences that provide major advantages in resolution slice coverage SNR and speed The new simultaneous imaging will have high utility and be highly desirable for use on clinical scanners worldwide The improved quantitative MRI blood flow imaging offers overall increased speed that is highly commercializable given they provide improved diagnostic approaches to evaluate diseases and further improve specificity and sensitivity in MRI exams The new technology will be designed implemented and evaluated on MRI scanners at University of California Berkeley University of California San Francisco UCSF Medical Center Harvard Medical School and Cedar Sinai Medical Center Once imaging protocols are optimized they will be further evaluated and optimized in collaborative clinical test sites in Europe including the major cardiovascular hospital in London the Royal Brompton Hospital and elsewhere In addition to establishing their value in medical exams the simultaneous phase contrast imaging will be made into useful tools for basic and clinical research PUBLIC HEALTH RELEVANCE Phase contrast PC imaging is the most used MRI technique to measure blood flow and cerebrospinal fluid flow non invasively for medical purposes It is commercially available on nearly all manufactured scanners and is the gold standard technique of flow imaging by MRI Its widespread use however is hampered by requiring several minutes of scanning time to obtain a single data set for velocity imaging We propose to develop a highly accelerated technique to obtain several PC images at different slice levels simultaneously rather than a single image slice and to achieve several times faster imaging The simultaneous quantitative imaging of blood flow and CSF flow will be highly valuable for medical diagnosis of cardiovascular and neurovascular diseases including stroke and be used as a general technique for a wide spectrum of diagnoses in the human body and for medical research

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

13 SBIR/STTR records share this UEI (2002–2021). Reported award amounts total $14,513,240. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.