SBIR/STTR Research Award

HIGHLY EFFICIENT CEREBRAL PERFUSION MRI

Award identifier a226696841b3cdea5efb534e21f4f29d8c4770a7342a0db84ff6d59a04c8e7c3Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,112,714

Program and phase

SBIR · Phase II

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ADVANCED MRI TECHNOLOGIES LLC
Proposal award date
2015-04-01
Contract end date
2019-03-31
UEI
JJ45PN66LSE7
Solicitation number
PA12-088
Topic code
108

Research abstract

DESCRIPTION provided by applicant MRI cerebral perfusion imaging is a widely disseminated technique on nearly all MRI scanners used for clinical diagnosis of brain disease and for neuroscience research Over the last five years there has been considerably increased use of arterial spin labeling ASL for clinical diagnosis while still i v injections of a gadoliium based contrast bolus are widely used clinically Both brain perfusion methods ASL and DSC techniques involve making images very fast to identify the passage of blood through the capillary compartment The image signal to noise ratio SNR is limited by the small e g fraction of blood in tissue volumes This is proportionately small but a second limitation is the time window of imaging which is constrained to about milliseconds for the capillary phase of blood passage Therefore rapid imaging of blood inflow is essential For this reason DSC contrast based methods and ASL with multi slice D EPI have not been able to satisfactorily image perfusion in the entire brain except with thick slices hence reduced spatial resolution D imaging has therefore been developed as an alternative to D EPI However D images have certain desirable characteristics compared with D if there are patient motion artifacts To overcome these limitations we propose to develop novel technology to acquire images simultaneously instead of separately This approach called simultaneous multi slice imaging ASL SMS ASL and SMS DSC increases by several fold the number of images that are acquired during the limited time window of capillary perfusion phase so the whole brain can be imaged Another benefit of SMS ASL is that the time to scan the brain can be greatly reduced by avoiding repeated scans of different brain areas thus reducing motion artifacts A second major innovation in this project is the Hadamard encoded ASL which is highly useful in clinical studies where the blood arterial transit time ATT is not known as in normal aging of people The Hadamard ASL acquires images at several different inflow times TI to be sure to capture the capillary perfusion phase of blood in at least one set of images By acquiring the different TI values in a well defined sub bolus partitioning of the labeling period their combination gives separated images at the distinct TI with essentially x the SNR and half the net scan time as required by current methodology which acquires each TI data set independently and sequentially Both the Hadamard and the SMS can be combined for further improvements in SNR speed and spatial resolution This will highly impact the accessibility to patients and the robustness of the perfusion technology in clinical use The availability of the new simultaneous perfusion imaging technology will give clinicians and researchers the capability of performing significantly improved MRI perfusion measurements in patients and these improvements will impact the diagnosis of many different brain diseases including stroke leukoencephalopathies and degenerative diseases i e Alzheimerandapos s disease and Parkinsonandapos s disease Perfusion measurements of quantitative cerebral blood flow CBF and ATT are important quantitative biomarkers useful as physiological imaging in evaluating new drug therapies for brain diseases This family of new perfusion imaging techniques utilizes more efficient pulse sequences that provide major advantages in resolution slice coverage SNR and speed The new simultaneous imaging will have high utility and be highly desirable for use on clinical scanners worldwide The improved quantitative MRI perfusion imaging offers overall increased efficiency that is highly commercializable given they provide improved diagnostic approaches to evaluate brain disease and further improve specificity and sensitivity in MRI neuroradiological exams The new sequences will be designed implemented and evaluated on MRI scanners operating at Tesla at AMRIT at T at University of California Berkeley and at T and T at University of California San Francisco Medical Center and at Martinos Center for Biomedical Imaging Massachusetts General Hospital and Harvard Medical School Once the new perfusion sequences are optimized they will be further evaluated and optimized in collaborative clinical test sites of UCSF Medical Center UCLA and University of Pennsylvania In addition to establishing their value in neuroradiology exams they will be made into useful tools for basic and clinical neuroscience research PUBLIC HEALTH RELEVANCE MRI is a proven non invasive technique to measure blood perfusion in the brain by both arterial spin labeling ASL which traces the passage of blood into the brain and by dynamic susceptibility contrast DSC perfusion measurements which rely on the i v injection of a small amount of tracer material without involving radiation The widespread use of these promising techniques of MRI perfusion imaging have been prevented by the inefficiencies in the image formation process which is limited to sub segments of the whole brain or sacrifice detail when imaging the whole brain We are proposing to develop a highly efficient imaging technique which will give researchers and clinicians the capability to perform D and D perfusion images of the whole brain by recording images simultaneously rather than separately as is currently performed in all scanners The resulting quantitative measures of cerebral blood flow will very valuable for medical diagnosis and in research on neurovascular diseases including stroke and wide spectrum of neurological diseases including brain tumors as well as for medical research on neurodegenerative diseases including Alzheimerandapos s disease Parkinsonandapos s disease and for leukoencephalopathies including multiple sclerosis

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

13 SBIR/STTR records share this UEI (2002–2021). Reported award amounts total $14,513,240. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.