SBIR/STTR Research Award

Pulse Oximeter Innovation to Measure Pulsus Paradoxus and Respiratory Disease Severity

Award identifier a25cceffd4cf3429c694c2c143816deb16e5a1e5e7edca4f6d884253bab9922eAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$150,000

Program and phase

SBIR · Phase I

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Kestrel Labs Inc
Proposal award date
2016-06-07
Contract end date
2018-05-31
UEI
VT6HK9MLF2Y9
Solicitation number
PA14-071
Topic code
NHLBI

Research abstract

DESCRIPTION provided by applicant Asthma is the most common chronic childhood disease and the most frequent reason for hospitalization of children It is also the most common chronic respiratory disorder in adults It results in over million emergency department visits and about hospitalizations annually in the U S alone The National Institutes of Health NIH expert guidelines recommend the measurement of Pulsus Paradoxus the variation in systolic blood pressure that occurs with inspiration and expiration as a clinical standard for determination of acute asthma exacerbation severity and to help guide appropriate treatment and hospitalization decisions for these patients Currently however there are no invasive or noninvasive monitors for the automated measurement of Pulsus Paradoxus Worse still the only clinically available noninvasive technique is performed using a stethoscope and a blood pressure cuff and is so time consuming and difficult to perform in a clinical environment that compliance with this NIH recommendation is estimated at less than Given the well recognized clinical value of Pulsus Paradoxus and the enormous financial burden of acute asthma attacks on the healthcare system it is clear that an automated easy to use noninvasive monitor for Pulsus Paradoxus would improve patient care and reduce unnecessary hospital re admissions increase compliance with NIH recommendations and decrease healthcare costs associated with acute asthma This SBIR Grant proposal is designed to determine whether Pulsus Paradoxus information is contained in the raw pulse oximetry data and whether these data can be extracted and processed to provide an accurate noninvasive real time measurement of Pulsus Paradoxus What sets this grant up for success is the combination of expertise provide by having two principal investigators One is a clinical expert in asthma diagnosis and treatment including prior work studying current methodologies and research concepts for the measurement and use of Pulsus Paradoxus and the other has over years in the field of pulse oximetry technology and product development Once this proof of concept study is successfully completed Phase II work would include integrating this measurement into an existing pulse oximeter to provide easy to use real time measurement of this crucial parameter and to demonstrate that this capability could increase compliance with NIH guidelines from the current andlt to over in the clinical environment PUBLIC HEALTH RELEVANCE The blood pressure of a person changes slightly when they breathe in and out and the amount of this change increases significantly when a person is suffering an asthma attack The magnitude of this change in blood pressure called andquot Pulsus Paradoxusandquot is recognized as the ideal measurement to use to determine the best treatment for any given patient but unfortunately no current medical monitor or automated tool exists for measuring Pulsus Paradoxus The proposed work has an ultimate goal of adding this measurement capability to a very common medical monitor called the pulse oximeter

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

8 SBIR/STTR records share this UEI (2003–2020). Reported award amounts total $5,947,853. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.