SBIR/STTR Research Award

Rapid POC Toxin Assay using Aptamer-Functionalized Magnetic Nanoparticles

Award identifier b11333b2d2dbae6a7db7389796044920132febfb25c7f77e90b272d65eb63418Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$224,999

Program and phase

SBIR · Phase I

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Koronis Biomedical Technologies Corp.
Proposal award date
2016-01-15
Contract end date
2017-11-30
UEI
ZTSLEXFJM3J1
Solicitation number
HL14-011
Topic code
NHLBI

Research abstract

DESCRIPTION provided by applicant There is a need for the ability to perform rapid and specific bio monitoring of a wide range of toxins for use by clinicians environmental epidemiologists and emergency medical responders Ultra miniature GMR magnetic sensors based on very mature technology developed by the magnetic recording industry are well suited to form the basis of an innovative toxin assay system While the proposed approach can easily incorporate the parallel detection of multiple targets a single toxin Bisphenol A BPA will be specified in this feasibility demonstration Our multidisciplinary team will generate custom aptamers tailored to uniquely bind with BPA using the SELEX procedure These aptamers will use BPA molecules to connect functionalized magnetic nanoparticles MNPs to the GMR sensor surface for detection The sensor will be integrated with a microfluidic network within a disposable cassette to facilitate controlled analyte preparation introduction and testing Custom electronics will be developed to read out the GMR sensor and detect the presence of BPA The use of advanced technologies enables the extreme miniaturization of each individual component allowing the entire assay system to be used in the field at the point of care The proposed system combines the use of functionalized aptamers magnetic nanoparticles ultra miniature magnetic sensors and microfluidic system design techniques in a highly innovative solution to the problem of bio monitoring and the detection of a large family of chemical compounds in a patientandapos s environment PUBLIC HEALTH RELEVANCE Exposure to toxins that enter the bloodstream from both occupational and domestic environments is associated with a wide range of public health issues There is a need among public health researchers clinicians and first responders for bio monitoring in large populations One example of a toxin with widespread exposure is Bisphenol A BPA BPA is found in polycarbonate plastics and epoxy resins that are used in containers that store food and beverages such as water baby bottles and the plastic liners of metal cans Significant public awareness and scientific interest has been focused on the negative impacts of BPA exposure Decades of research have indicated that BPA plays a role in disrupting hormones affecting brain development and fertility and may promote chronic diseases in adulthood such as diabetes and cancer

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

74 SBIR/STTR records share this UEI (2005–2025). Reported award amounts total $36,358,935. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services, Department of Education, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.