SBIR/STTR Research Award

Intraoperative assessment of non-melanoma skin cancer margins using NIRF probes.

Award identifier f2a53b67f0ca4b29229c43db84bd641491bfda60cedf4f02b40f555a391eaf9fAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,669,473

Program and phase

SBIR · Phase II

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Akrotome Imaging, INC
Proposal award date
2015-09-25
Contract end date
2018-08-31
UEI
KM31KGPYM8Y1
Solicitation number
PA14-071
Topic code
102

Research abstract

DESCRIPTION provided by applicant It is predicted that approximately people will be diagnosed with nonmelanoma skin cancer this year in the United States Seventy five percent of these patients will undergo traditional excisional surgery i e non Mohs Micrographic Surgery non MMS Unlike MMS surgery traditional excision surgeries do not employ methods to determine the status of the margins of resected tissues during the surgical procedure Instead the size of margins to be resected is determined by the size and differentiation of the lesion observed during pre surgical examination and diagnosis Resected specimens are forwarded to pathology where they undergo formalin fixation paraffin embedding staining and analysis with results available days post surgery In general these are larger lesions so only a limited portion approximately of the margin is analyzed by pathologists to deduce if the surgery removed all of the cancer Normally to ensure total removal of the cancer and prevent re excision more aggressive margins up to mm may be taken with non MMS than with MMS surgery With MMS less aggressive margins are taken but are immediately subjected to iterative frozen section analysis with of the margins analyzed during the surgical procedure MMS achieves up to cure rates and significantly limits the morbidity compared to non Mohs procedures However MMS is not available at all dermatology facilities nor is it considered appropriate use for approximately of non melanoma skin cancers Therefore the majority of skin cancers undergo conventional surgery followed by pathological analysis to determine if all the cancer was removed However non MMS procedures do not has the same cure rates as MMS and substantial numbers of patients are forced to return for re excision of cancer andquot missedandquot during the initial skin cancer excision Therefore there exists an unmet clinical need to assess surgical margins during non MMS procedures reducing the number of re excisions and potentially impacting patient outcomes Development of a simple rapid and global imaging technology to rapidly and intra operatively identify cancer in resected tissues during surgery could bring MMS like results to non MMS skin cancer resections In our a technology a quenched protease selective optical imaging probe is used to identify skin cancer both basal cell and squamous cell carcinomas after a topical application of the probe to excised skin cancer tissues Our technology achieves sensitivity and specificity In this proposal we have brought together two partners INDEC Systems Inc camera technology and Case Western Reserve University assessment of instrument performance coordination with UH clinicians to drive to the clinic a product capable of impacting the way skin cancers are resected We propose the development and testing of a andquot complete solutionandquot to assess excised skin cancer margins Our complete approach topically applies a quenched protease selective imaging probe to excised tissues and then images these tissues in a dedicated imaging device to identify the location of both cancer and normal skin PUBLIC HEALTH RELEVANCE The goal of this Phase II SBIR project is to develop and deploy a andquot total solutionandquot for assessing skin cancer margins during conventional resection of BCC and SCC This project will bring together a corporate leader Akrotome and instrument company Indec Systems and an academic partner CWRU

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

5 SBIR/STTR records share this UEI (2011–2022). Reported award amounts total $4,147,784. Reported amounts are not federal obligations.

Phases: Phase I, Phase II – Direct to Phase II, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.