SBIR/STTR Research Award

Valvuloplasty Sizing Balloon Catheter

Award identifier b3b6fdaebb76bc054077f1bac66c5e49d8dce278d885c6f6bd76a8f6ad6fc531Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$237,021

Program and phase

SBIR · Phase I

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
3DT HOLDINGS, LLC
Proposal award date
2015-04-01
Contract end date
2016-12-31
UEI
E527XPXM1CJ7
Solicitation number
PA14-071
Topic code
NHLBI

Research abstract

DESCRIPTION provided by applicant Severe aortic stenosis AS is a serious medical condition that can ultimately lead to death but is often left untreated because of high perioperative surgical risk As a result transcatheter aortic valve replacement TAVR therapy has emerged as a percutaneous approach for prosthetic aortic valve delivery for the treatment of AS Complications following TAVR are related to paravalvular leakage which has been linked in part to inaccurate prosthetic valve size selection compared to the true native aortic annulus size Although imaging modalities are used to assess aortic valve annulus size prior to TAVR these methods are subjective can be inaccurate and also add additional time cost and clinical procedures Since it is standard procedure to perform valvuloplasty just prior to valve deployment annular sizing information can be obtained from the valvuloplasty balloon and used to select the proper valve size The pressure diameter relationship of the balloon could be useful here however non uniform balloon expansion makes sizing of the aortic valve annulus difficult for semi compliant valvuloplasty balloons Consequently we have developed a novel sizing valvuloplasty conductance balloon SVCB catheter system that functions as a typical valvuloplasty balloon catheter but with additional functionality for accurate display of real time balloon size for aortic annulus assessment using electrical conductance measurements This is unlike other systems that rely on standard pressure diameter relationships to acquire balloon size across the entire balloon Rather our system uses an electrical law of physics to obtain precise annular dimension despite any asymmetries that could arise in the balloon dimension during inflation The sizing results are displayed in real time on a simple bed side console display to aid the physician during balloon expansion i e similar to current displays that show pressure during inflation The preliminary results with our SVCB catheter system on the bench and in healthy swine showed excellent accuracy diameter error as was the repeatability andlt diameter error and safety no arrhythmias or death However additional work is needed to refine the console and catheter and to further validate the system in diseased swine this Phase I application before translation to man future Phase II application Therefore in this Phase I application we propose the creation of a clinically ready SVCB catheter system and its validation in vivo in diseased swine Based on the physics foundation of the technology and the excellent preliminary sizing and safety results the SVCB catheter system is expected to provide highly accurate and repeatable real time digital display of aortic annulus size with virtually no physician training required This project has the ability to impact patients with multiple comorbidities and reach across various NIH Institutes and Centers including the NHLBI and NINDS PUBLIC HEALTH RELEVANCE A device that increases accuracy reduces costs adds no time eliminates the need for user interpretation for measurements and fits well within the clinical workflow is needed for aortic annulus size determination prior to transcatheter aortic valve replacement TAVR The purpose of this Phase I proposal is the refinement and validation in diseased swine of a clinically relevant valvuloplasty sizing conductance balloon catheter system that relies on electrical voltage measurements to provide accurate real time sizing measurements during valvuloplasty and TAVR procedures

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

29 SBIR/STTR records share this UEI (2010–2025). Reported award amounts total $17,062,625. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.