SBIR/STTR Research Award

Novel Silica-Based Organic Polymer for Ambient Ionization Mass Spectrometry

Award identifier 13eac2f57c6f1d2366c60c23c625a803f1039f485b5638b43ce30d225c330397Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$161,710

Program and phase

STTR · Phase I

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Prosolia, Inc.
Proposal award date
2015-01-01
Contract end date
2015-12-31
UEI
CJE7YFUBN1C5
Solicitation number
PA14-072
Topic code
NIGMS

Research abstract

DESCRIPTION provided by applicant Most samples of chemical interest are complex mixtures making the usual combination of chromatography with mass spectrometry MS a natural choice However the increased demand for chemical analysis by mass spectrometry in many areas of science makes it imperative to increase efficiency of analysis by minimizing sample workup and overall analysis time which makes direct mixture analysis highly desirable These demands were in many ways solved in with the development of ambient mass spectrometry a branch of mass spectrometry which allows spectra to be recorded on samples in their native state with minimal or no sample preparation Ambient ionization provides the speed needed for in situ experiments by recording mass spectra instantaneously on unmodified samples in their native state and in the ambient environment Sample analytes are loaded onto a substrate material for sampling and supporting the analytes to be studied Nonpolar substrate surfaces currently used in ambient MS offer an advantage over other existing materials in the analysis of a variety of analytes but have limited utility in that they often are impure mechanically weak single use offer poor sample loading have decreased signal intensity and stability and are not easy to modify making them useful for only a particular class of analytes As an alternative to the more widely used sampling materials such as paper and glass we have developed novel organosiloxane OSX polymer materials that have the potential to be used as sampling substrates in ambient ionization methods Our materials can be chemically tuned to increase signal intensity molecule selectivity signal stability and can also be chemically modified by covalent attachment of molecules to serve different analytical purposes within many other possibilities In Aim we will investigate and optimize the synthetic parameters that affect the polymer features such as its porosity polarity hydrophobicity hydrophilicity and its surface features and chemistry In Aim we will use the OSX polymer as a sampling material in spray ionization and desorption electrospray ionization DESI MS to evaluate the performance of the polymer and to identify the optimal operating conditions signal intensity and stability for the polymers investigated and designed in Aim In Aim we will evaluate the feasibility of coupling the polymers to as commercial ambient MS using Prosoliaandapos s commercial robotic sources To assess the utility of these OSX polymers as sampling materials we will analyze drugs in blood serum and study in situ digestion of proteins on polymer surfaces grafted with an enzyme Given the many advantages of OSX polymers they will make excellent commercial products that can widen the application of ambient ionization MS in many different areas including clinical medical diagnostics and proteomics PUBLIC HEALTH RELEVANCE Ambient mass spectrometry has been increasingly used in many areas of science such as forensics clinical diagnostics and drug analysis as it allows for direct and fast detection of samples However there are limitations in the sampling materials currently used for ambient mass spectrometry We propose to develop and test novel improved sampling materials that can be chemically modified for improving the performance of ambient mass spectrometry analysis and expanding its use

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

5 SBIR/STTR records share this UEI (2009–2019). Reported award amounts total $1,503,557. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.