SBIR/STTR Research Award

Development of a Novel Atmospheric Pressure Glow Discharge for Ambient Mass Spect

Award identifier 098212b6ffa227b205f7f66f30493bdbd6aeaa7063df0ba2f8d4774f708cd87aAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$740,795

Program and phase

STTR · Phase II

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Prosolia, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
CJE7YFUBN1C5
Solicitation number
PA10-051
Topic code
NCRR

Research abstract

DESCRIPTION (provided by applicant): The overall objective of this Phase II STTR project is the commercialization of a new ionization source for ambient mass spectrometry based on the flowing afterglow of an atmospheric pressure glow discharge. This technology promises to have significant impact in pharmaceutical, clinical and biomedical research. Ultimately, we envision commercial ion sources that can be easily switched among several atmospheric pressure ionization techniques and can be retro-fitted to several different types of mass spectrometers or ion mobility spectrometers. Phase I of this project was highly successful. Alpha prototypes were developed, tested and feasibility proven. Optical spectroscopy measurement revealed novel species (He2+), whichare implicated in the ionization mechanism. Further, the plume temperature measurements revealed hot spots' within the afterglow where thermal desorption is most efficient and results in higher sensitivity. We demonstrated that the ion source could directly desorb and ionize a variety of chemical species and further tested the method in the direct analysis of mycobacterium smegmatis cells. Finally, the coupling of the ion source to a laser ablation cavity proved to yield molecular information with high spatial resolution. The phase II specific aims are as follows: 1. Prototype Development. Beta prototypes of the FAPA ion source will be designed and built based on the criteria defined at the conclusion of the Phase I grant. The sources will include the development of an optimized FAPA discharge cell and a mass spectrometer mounting system with computer controlled sample positioning system. Additionally, prototype support electronics, including the constant current, high voltage DC power supply, a discharge gas temperature controller, and a discharge gas flow controller. Finally, software will be developed to control these elements and automate sample collection. There will be a minimum two beta prototypes built for testing and validation simultaneously at Indiana University and Prosolia. 2. Characterization and Optimization of the sampling process at atmospheric pressure: We will use schlieren photography in combination with mass spectrometry and computer simulations to provide the ideal sampling environment at the interface between the reagent ion gas plume and the vacuum inlet to the mass spectrometer. 3. Source Characterization and applications development: Our approach is three-fold: 1) to test and characterize the beta prototype FAPA source developed in Aim 1 by examining neat samples while varying the gas flow, heater temperature, and device impact angle and assessing the usual figures of merit, detection limits, precision, accuracy, carry-over, and throughput; 2) examining the effects of modifying gas phase chemistries to effect atmospheric pressure fragmentation reactions for generating NIST searchable spectra; and 3) to apply the optimal device parameters, gas-phase chemistry and sampling conditions to a combinatorial study of one hundred drug-like molecules of various properties and compare the results to the same study by DESI. We believe it is important to show our customers a range of molecules in size and hydrophobicity to make it easier for them to assess the likelihood their proposed applicationwill be successful. Upon successful completion of the proposed aims, Prosolia will proceed into phase III commercialization where FAPA ion source products (hardware and software) and services will be commercialized. Further, strategic licensing and partnerships will be secured to commercialize the technology as an add-on accessory to laser ablation cavities, gas chromatographs and/or liquid chromatographs. PUBLIC HEALTH RELEVANCE: Prosolia's new and versatile ambient ionization source for mass spectrometry promises to enable high throughput chemical screening that will significantly impact pharmaceutical, clinical and biomedical research.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

5 SBIR/STTR records share this UEI (2009–2019). Reported award amounts total $1,503,557. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.