SBIR/STTR Research Award

Enhancing longevity of implanted medical devices

Award identifier e33f1bfa8836e6a3a691c848270d1215b68b2ef631666b8f9d58a2d2a3ed20acAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$158,643

Program and phase

SBIR · Phase I

Award year

2014

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
PIEZO ENERGY TECHNOLOGIES LLC
Proposal award date
2014-09-30
Contract end date
2016-06-30
UEI
XPEZLZF5P8N6
Solicitation number
PA14-071
Topic code
NIBIB

Research abstract

DESCRIPTION provided by applicant Advanced methods for wirelessly recharging batteries for implanted medical devices are needed The useful lifetime of most implants is constrained by the longevity of the power source The goal of this program is to implement the development of an UltraSound Electrical Recharging system USerTM within a clinically deployed gastric sphincter stimulation system A successful Phase I will lead to expanded use of an existing therapeutic device and also demonstrate the potential of USerTM as a power platform for many other implants This combination of power delivery and therapy is innovative While the ultrasound transmit and receive technique has long been used for materials testing to our knowledge it has never been employed for wireless power delivery to medical devices The proposed project will influence technical capability and hence clinical practice The present method of recharging implantable batteries has been via electromagnetic induction Although useful it has its limitations such as the depth of tissue through which it can effectively transmt the use of increasingly crowded electromagnetic frequencies and the propagation of stray electromagnetic fields into the body and the local environment Ultrasound recharging can provide another option in cases where the electromagnetic induction method does not suffice reduce exposure to radiation and avoid conflicts due to overlapping uses of the same electromagnetic frequencies The specific aims will deal with questions that must be answered to prove feasibility The aims are to show that the power required for the application can be delivered within the geometrical constraints of the implant that the charging circuitry previously developed can be substantially miniaturized to fit into the implant and to conduct in vivo tests o the system The wireless power transmission technology is based on well known principles of ultrasound which is known for its safety in diagnostic applications The potential advantages include smaller transmitters and receivers elimination of electromagnetic interference and heating of metal parts and the transmission of power to deeper sites in the body This new technique will drive new therapeutic applications hence improving medical options to combat medical conditions The USerTM technology will support the NIH mission in its goals of improving human health and reducing healthcare costs This will be done by minimizing the distress and complications caused by battery replacement operations by increasing the implant functions via providing more power by improving patient satisfaction and compliance and by reducing operations to replace batteries and other components PUBLIC HEALTH RELEVANCE Ultrasound wireless energy transfer will extend the lifetime of implanted medical devices and make associated therapies accessible to patients suffering from a variety of conditions Most implanted devices currently use permanent batteries which need to be replaced periodically or electromagnetic recharging Ultrasound wireless power transfer offers another power delivery option to advance public health goals by reducing infections distress pain and complications associated with replacing batteries and avoiding radiation and other concerns with the electromagnetic method As a result health care costs will also be reduced significantly

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

4 SBIR/STTR records share this UEI (2006–2014). Reported award amounts total $993,605. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.