Solid State Sensor System for Inspection of Prestressed Concrete Pressure Pipe

Award identifier 2712e749e505e63feab0f6467988ccfb62e1499baf3c81471d7ee639950533b5Awarding agency Environmental Protection Agency

Award amount

$80,000

Program and phase

SBIR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Environmental Protection Agency
Branch
Not reported
Recipient company
RADIATION MONITORING DEVICES, INC.
Proposal award date
2013-05-15
Contract end date
2013-11-13
UEI
SCKQA85YU4U4
Solicitation number
Not reported
Topic code
A

Research abstract

An important type of water pipe is the Prestressed Concrete Cylinder Pipe (PCCP). There are thousands of miles of PCCP installed in the US in sections with length up to 20 feet and diameter for 2 to 14 feet. The large size of the pipes, the thickness of the concrete (up to 10 inches) and the composite construction, which involved concrete, high strength prestressing steel wires and sheet steel cylinders, make inspection particularly challenging with existing technology.§Degradation in PCCP is characterized by corrosion that breaks one or more prestressing wires thus weakening the pipe until it fails and a leak is created. Leaks are among the largest sources of water loss and technology for detecting damage in the prestressing wires in PCCP would provide a majorenvironmental benefit for the nations, its water resources and water utilities. Existing sensor technology, based on decades-old eddy current test systems, lacks the sensitivity and signal to noise ratio needed to make rapid, high reliability inspections of PCCP. §RMD proposes a new, highly optimized probe for PCCP that uses a solid-state, field sensitive sensor offering high sensitivity and low noise at low frequencies combined with a novel, low noise eddy current source to greatly improve PCCP inspection. §In Phase I, RMD will develop a prototype probe for PCCP, measure the response of the probe to PCCP samples with and without defects to the prestressing wires, and compare the results with those obtained using a state-or-the-art ECT system for PCCP. A successful Phase I/II SBIR program will lead to improved PCCP inspection, less water loss and improved environmental safeguards for drinking water. Commercialization will result in a new product that will enhance the safety and reliability of water systems, and reduce lost water and downtime for water utilities.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

930 SBIR/STTR records share this UEI (1983–2026). Reported award amounts total $346,950,619. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration, National Science Foundation, Department of Homeland Security

Agency intelligence

Environmental Protection Agency

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.