SBIR/STTR Research Award

TIBr Spectrometers with Improved Long Term Stability at Room Temperature

Award identifier e80481e9ac420e2e0ca5ee16039c1b2f4afb9060de6d0387308907a2c98f5a2aAwarding agency Department of Homeland Security

Award amount

$149,999

Program and phase

SBIR · Phase I

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Homeland Security
Branch
Not reported
Recipient company
RADIATION MONITORING DEVICES, INC.
Proposal award date
2012-09-21
Contract end date
2013-03-20
UEI
SCKQA85YU4U4
Solicitation number
Not reported
Topic code
2012.1-004

Research abstract

The ideal semiconductor detector for the nuclear non-proliferation application should have good energy resolution, high detection efficiency, compact size, light weight, easy portability, low power requirments and low cost. In the proposed effort, we plan to continue our development of thallium bromide (TIBr), a wide band gap semiconductor that recently has shown great promise as a gamma-ray detector material. In addition to high density (7.5 g/cm2), high atomic number constituents (81,35) and wide band gap (2.68 eV) the material melts congruently at a modest temperature (480°C) and does not undergo a phase change as the crystal cools to room temperature, which allows use of melt-based crystal growth approaches to produce large volume TIBr crystals. The cubic crystal structure of TIBr also simplifies crystal growth and device processing. As a result of recent progress in purification, crystal growth and processing, TIBr detectors with mobility-lifetime products of mid 10^-3 cm2/V for electrons and mid 10^-4 cm2/V for holes has been achieved. This has enabled the development of TIBr gamma-ray spectrometers with thickness exceeding 1 cm. TIBr detectors fabricated in our lab have exhibited < 1% energy resolution (FWHM) at 662 keV with cooling and depth correction. To date, to obtain excellent long term performance of thick TIBr detector arrays, modest cooling (to ~-20 C) has been requied. We have demonstrated stable TIBr detector performance exceeding 9 months with the detector continuously biased and operated at ~18°C. This level of cooling is easily achieved with thermoelectric cooler. Cooling however, does increase the power budget of a detector system. In addition to cooling as a method to obtain long term TIBr detector stability, research at RMD and elsewhere has shown that surgace processing, electrode materials and thermal annealing significantly influence the long term stability of TIBr detectors operated at room temperature. RMD and its affiliated research teams have demonstrated thin TIBr detectors with long term stability exceeing 50 days at room temperature. It is our goal in this program to further investigate the effects of surface processing, electrodes and annealing on long term stability of TIBr detectors operated at room temperature. In addition, doping will be investigated as a method for modifying ionic conductivity. Dr. Harry Tuller's group at the materials science department of MIT will collaborate with RMD on this aspect of the project. Ultimately our goal is to develop TIBr spectrometers that are stable for more than 1 year at room temperature. Such as efficient, high resolution detector will find applications in nuclear monitoring areas such as nuclear treaty verificiation, dafeguards, environmental monitoring, nuclear waste cleanup, and border security. Nuclear and particle physics as well as astrophysics are other fields of science were gamma-ray spectrometers are used. The developed detectors should have the following advantages: · Efficient detection of gamma-rays (better than CZT per unit volume ·Energy resolution < 1% (FWHM) at 662 keV at room temperature · Lower cost than CZT-based system due to lower cost crystal growth

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

930 SBIR/STTR records share this UEI (1983–2026). Reported award amounts total $346,950,619. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration, National Science Foundation, Department of Homeland Security

Agency intelligence

Department of Homeland Security

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.