Isotopic Carbon Dioxide Analyzer for Flux Measurements

Award identifier 11d4cd0249bb794559033962e132f22e78bfac7cc5561d69f5b50c414054383eAwarding agency Department of Energy

Award amount

$148,708

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
Los Gatos Research
Proposal award date
2011-06-17
Contract end date
2012-05-16
UEI
MYRGAPL7LDK6
Solicitation number
DE-FOA-0000413
Topic code
29 b

Research abstract

Los Gatos Research, Inc. (LGR) proposes to develop a rugged, field-deployable, Off-Axis Integrated Cavity Output Spectroscopy (Off-Axis ICOS) instrument for atmospheric carbon dioxide isotopic flux measurements. The instrument will provide highly accurate and precise measurements of 12C16O18O, 13C16O16O, and 12C16O17O, for the determination of CO2, 13C and 18O and 17O in CO2 in ambient air at high measurement rate (10 Hz) for direct determination of fluxes. In addition to continuous measurements of CO2 in air, the instrument will be capable of discrete measurements of batch samples via syringe injection. The detailed understanding of atmospheric chemistry, greenhouse gas emissions and sequestration, and pollution transport in the troposphere, on large and small spatial scales, is limited by the availability of reliable, sensitive, and accurate instrumentation that is easy to use, economical and yields rapid, real-time results. This project will develop a novel, rugged instrument that sensitively and accurately measures the flux of CO2, 13C and 18O (and possibly 17O) in CO2 in ambient air. The instrument, based on LGRs patented cavity-enhanced absorption spectroscopy technology called Off-Axis Integrated Cavity Output Spectroscopy (ICOS) and on state-of-the-art room-temperature continuous-wave quantum-cascade lasers, will be simple to use and will provide fast, real-time measurements in the field from diffuse sources (continuous flow mode) and from discrete point sources (batch sample mode). The Phase I prototype instrument will be tested under realistic conditions on calibrated gas mixtures to determine the accuracy, precision, sensitivity and time response. The Phase I prototype instrument will also be deployed for eddy covariance flux measurements (peatland ecosystems, at AmeriFlux site) to establish the ruggedness, reliability and time response of the instrument in the field. Finally, a Phase II instrument will be designed for autonomous long-term measurements, and the costs of building and selling instruments in small and large quantities will be quantified. In Phase I, LGR will demonstrate technical feasibility by fabricating an Off-Axis ICOS instrument employing a novel, room-temperature continuous-wave, commercially available quantum cascade laser operating near 4.3 microns (CO2 fundamental vibration band), capable of measuring 12CO2, 13C and 18O (and 17O) in ambient air continuously and in batch samples (via syringe injection). Several significant improvements to LGRs standard technique will be implemented (including improved data analysis methods, higher power and lower noise mid-IR laser, lower photodetector noise, improved optical configuration and noise filtering, faster data acquisition rate and temperature stabilization) to enhance the system performance to achieve 0.3 precision at a 10-Hz measurement rate (0.1 seconds per measurement point). This performance will be confirmed by measuring a series of calibrated CO2 standards (obtained from NOAA CMDL Carbon Cycle Group) whose concentrations and isotope ratios are known to better than 0.1 ppmv and 0.02. Finally, the isotope flux measurement system will be configured with a batch injection system for measurements of discrete gas samples where sample size is limited. This comprehensive carbon dioxide isotope instrument will have low power requirements (less than 300 watts) to facilitate field use, low sample volume requirements (2.6 mL) to minimize consumption of sample and calibration gas, report data quickly (10 Hz) and enable detailed characterization of isotopic carbon dioxide distributions over large and small spatial scales.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

160 SBIR/STTR records share this UEI (1994–2013). Reported award amounts total $47,120,524. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: National Aeronautics and Space Administration, Department of Defense, Department of Energy, National Science Foundation, Department of Health and Human Services, Department of Agriculture

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.