SBIR/STTR Research Award

High Z Semiconductor Gamma-Ray Detector for Nuclear Non-Proliferation

Award identifier b591ad2c35aa8f9289c4b46f30812797ee614ce4cbb9d282c80e5a29af35ac4cAwarding agency Department of Energy

Award amount

$149,999

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
RADIATION MONITORING DEVICES, INC.
Proposal award date
2011-06-17
Contract end date
2012-05-16
UEI
SCKQA85YU4U4
Solicitation number
DE-FOA-0000413
Topic code
51 b

Research abstract

There is a critical need for low cost, high performance gamma-ray detectors for identification and localization of special nuclear materials (SNM) such as plutonium and weapons grade uranium. Cadmium zinc telluride (Cd1-xZnxTe or & quot;CZT & quot;) has emerged as the leading room temperature semiconductor gamma ray detector. However, despite decades of research and recent improvements in crystal growth and processing techniques, the yield of device grade CZT is low. To meet the needs of homeland security a lower cost alternative to CZT is desirable. In the search for semiconductors that have potential for higher intrinsic detection efficiency than CZT and potentially lower cost, lead-containing chalcogenides have been identified as promising candidates. These materials have several favorable properties for room temperature gamma-ray detection including high Z (due to Pb), wide band gap (1.6 eV to 2.8 eV range) and can exhibit high electron mobility and no ionic conductivity. The goal of the proposed project is to investigate growth of high quality crystals of PbGa2Se4 and then implement advanced detector designs based on such detectors. Commercial Applications and Other Benefits: In addition to nuclear non-proliferation, nuclear medicine, computed tomography and non-destructive testing are other applications where high performance, less expensive spectrometers will have beneficial applications. One medical application that RMD already takes part in is the production of surgical probes used for localizing radiopharmaceutical uptake. These tools have become part of a technique (sentinel node biopsy) that minimizes the debilitating nature of removing lymph nodes in monitoring the spread of breast cancer. As this technique has become more accepted for breast cancer, other treatment areas have been considered such as monitoring PET isotopes (emitting at 511 keV) which have greater specificity to cancer sites. A high energy emission presents a challenging probe design because of scattering and lack of efficiency. New large PbGa2Se4 detectors capable of scatter rejection would be a very welcome solution if available

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

930 SBIR/STTR records share this UEI (1983–2026). Reported award amounts total $346,950,619. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration, National Science Foundation, Department of Homeland Security

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.