SBIR/STTR Research Award

Design and Testing of a Water Based Fire Extinguishing System for On-Board Hydrogen Peroxide Fires

Award identifier 1c8f2ea22a40b8b0cd71137cde1d0341f514b8f467b5ee0464c462a25e22a660Awarding agency Department of Defense · Missile Defense Agency

Award amount

$99,949

Program and phase

STTR · Phase I

Award year

2004

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Missile Defense Agency
Recipient company
STREAMLINE AUTOMATION LLC
Proposal award date
2004-08-31
Contract end date
2005-02-28
UEI
CLW2B8WVV1D4
Solicitation number
Not reported
Topic code
MDA04-T004

Research abstract

The Air Force has demonstrated that a water is capable of extinguishing comparable H2O2 oxidizer fires with 23 pounds of water vs 67 pounds of halon. Recent advances in sensor technology make it possible to detect an H2O2 leak prior to ignition, or to rapidly detect ignition in order to initiate fire protection system water flow. Recent findings by Streamline Automation also indicate that fire extinguishing enhancement is possible via electrostatic charging of the water mist. Streamline Automation and Worcester Polytechnic Institute will leverage advanced sensors, and explore the impact of electrostatic charging, to provide a more effective H2O2 fire extinguishing system for ABL than the current Halon system. During Phase I Streamline Automation proposes to: 1.Develop a water mist fire extinguishing system that incorporates an advanced H2O2 sensor developed by Argonne National Laboratory and a rapid response COTS flame sensor. 2.Adapt our electrostatic charging approach to Fike Corporation's P/N 73-010 micro-mist nozzle. 3.Demonstrate a system (water and hardware total weight less than 75 pounds) able to extinguish an obscured "Red Mechanic's Rag" fire at any location on the floor of the 8x10x10 ft fire test chamber at WPI. Streamline Automation has teamed with the WPI Fire Science Laboratory, a premier University in fire science, to assist in optimizing our charged water mist system during Phase I development testing. The Phase I test matrix will include multiple fire energy levels and water mist flow rates, both with and without electrostatic charging. During Phase II CFDRC will develop and provide for test a prototype Fire Extinguishing System (total weight < 5000 lbs) scaled to protect all likely H2O2 spill locations in the laser and laser chemical supply areas of the Airborne Laser, Block 08 installation.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

75 SBIR/STTR records share this UEI (2003–2024). Reported award amounts total $23,124,794. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, National Aeronautics and Space Administration, Department of Homeland Security, National Science Foundation, Department of Energy, Department of Health and Human Services

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.